In accordance with their intended use Pony FX is not to be handled together with other medical devices unless it is clearly declared by the manufacturer itself. indicates a messages shown by the firmware. COSMED Spirohometer Spirometer Service Manual, Cosmed does not assume the liability for interpretation mistakes of, COSMED Srl SN7-K4B2T-USA TELEMETRYUNIT User Manual, COSMED Srl SN7-K4B2R-USA TELEMETRYUNIT User Manual, COSMED does not assume any liability for end user, Midmark Digital Spirometer Quick Reference Guide, COSMED does not assume any liability for end user interpretation of, Gima 33478 NUVOAIR NEXT SPIROMETER Owner's Manual, COSMED Srl SN7-COSMED-K5 Wearablemetabolic system User Manual, Contraindications for the Spirometer tests, Contraindications for Bronchial provocation tests, VC/IVC - Slow Vital Capacity and Ventilatory pattern, Connect the Pony FX to an external printer, Printing tests by means of the internal printer, Printing tests by means of an external printer, Perform the FVC test with the encouragement, Methacholine and Histamine Bronchial provocation Tests, Precautions during the cleaning of the turbine, Return goods policy for warranty or non warranty repair.

Atmospheric Pressure range 700 to 1060 mBar. It is not allowed performing tests with Pony FX connected to the mains. Near the keyboard, a led indicates the battery status: Battery temperature <5C. All bibliography references are reported in Appendix. If you use an external printer, it must support the PCL language and have an USB port for data transmission. This user manual is to be considered as a part of the medical device and should always be kept on hand. It is recommended to use a computer with electromagnetic compatibility CE marking and with low radiation emission displays. If the printer connected to the Pony FX is placed within the patient area (according to the IEC 60601-1-1 norm), it has to be made compliant with the IEC 60601-1-1 norm by means of an isolation transformer. Find reported below the complete classification of the device: Internally powered equipment type BF device (used stand alone), class II type BF device (used connected to mains), Protection against water penetration: IP00, ordinary equipment unprotected against water penetration. These are the graphic keynotes used in the manual. It is connected to the unit through the Turbine connector. Pony FX can be connected to a PC in order to transfer and store the performed tests, to view the tests and, if it is used the medical grade battery charger, to perform the tests and display them on the PC monitor. Predicted value FEV1 less than 1.51 in men and predicted value FEV1 in women less than 1.21.

Avoid to use it in presence of noxious fumes or dusty environment and near heat sources. Here are the keynotes used to make the manual easier to read. PC conform to European Directive 89/336 EMC, Flowmeter (pneumotachograph or turbine, depending on the version). On the bottom side of the device there are 7 connectors, as shown in the following picture. Connector for the turbine flowmeter or for the airway resistance measurement module (option). Enter your email address and check your inbox. Before using the system, please take a moment to fill in the registration form and the warranty and return them to COSMED, by doing this you are eligible to the customers assistance service. Avoid to use it in presence of noxious fumes or dusty environment and near heat sources. Enter a new Bronchial provocation protocol in the.

Box n. 3, email: customersupport@cosmed.it Internet: http: //www.cosmed.it. The first time you connect the Pony FX to the PC through an USB connection, you will be requested for the drivers. Cosmed does not assume the liability for interpretation mistakes of this documentation or for casual or consequential damages in connection with the provision, representation or use of this documentation. * Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project.

This window is provided with a series of fields in which input the information. Ce site utilise des cookies et autres technologies similaires, Remarque! In particular grounding reliability and leakage current suppression can only be assured when the device three wire receptacle is connected to a yellow - green return connected to earth ground.

The keyboard is divided into two groups. In the left one there are the on/off-menu key (at the centre) and four direction keys. Safety, measure accuracy and precision can be assured only: using the accessories described in the manual or given with the device. Pony FX is a device designed for lung function screening; the core of the system is the intelligent flowmeter, connected to the main unit, with graphical colour display. Recent infection in the superior air tracts. Otherwise, use the serial RS232 connection.

Moderate or serious bronchial obstruction. Pony FX est la nouvelle gnration de spiromtres de bureau dveloppe par COSMED pour la spiromtrie complte (FVC / SVC, MVV, provocation bronchique) et la mcanique respiratoire (MIP / MEP, Rocc). Reproductibilit leve et haute corrlation les mesures en cabine de plthysmographie, Idal pour les mesures sur des sujets peu collaborants : enfants, patients souffrant de pathologies svres, difficult de communication, Oxymtre et capteur dans une seule unit autonome, Performances prcises dans des environnements de surveillance difficiles avec niveaux critiques de SpO2, Haute efficacit de filtration virale et bactrienne (99,999%), Convient la fois la fonction pulmonaire et aux tests d'effort, Emball individuellement dans une bote de 50 pices, Seringue d'talonnage certifie en aluminium de 3 litres, Prcision: 1/2 de 1% de la pleine chelle, Butes rglables pour des volumes de course plus petits supplmentaires, Norme d'talonnage selon les directives ATS / ERS. Install the software from the original disk.

Moderate or serious bronchial obstruction. The red led should switch off when the temperature falls again in the range, Battery temperature >45C. The red led should switch off when the temperature falls again in the range 5-45C. 3.Before powering the system, check the power cables and the plugs. If you would like to perform test with Pony FX connected to the mains, use the medical version battery charger (see Installation chapter). It is not an AP nor an APG device (according to the EN 60. Many of the functions that may be selected from the menu can be activated more rapidly by clicking with the mouse on the corresponding icon in the tool bar. Incapacity for understanding the provocation test procedures and its implications. Aspiration of contaminates can potentially be life-threatening. The device, the program algorithms and the presentation of measured data have been developed according to the specifications of ATS (American Thoracic Society) and ERS (European Respiratory Society). For more information about the use of the internal (or an external) printer, see the chapter Using Pony FX. Ce site utilise des cookies et autres technologies similaires.

The colour display interfaces the device with the user, allowing the user to access to the functions of the device and to display the performed tests. Press the Enter key to confirm the information input on the dialog box or press the Esc key to cancel changes. Internal temperature sensor: 0-50C (32-122F), (class II according to EN 60 601-1 standard). Quality Control Messages . References Pony FX is an electrical medical device designed to perform pulmonary function tests. Make sure that the package contains the items listed below. Note: The first time you use the device, charge the battery for at least 12 hours, even if the led indicates the completion of the charge before the time elapsed. Some functions of the program are "active window" sensitive (Print, right key of the mouse). The red led should switch off when the temperature falls again in the range. 9.It is recommended to use a computer with electromagnetic compatibility CE marking and with low radiation emission displays. The program will load up a dialog box and ask for a directory where to be installed. 5.Cleaning residue, particulates, and other contaminates (including pieces of torn or broken components) in the breathing circuit pose a safety risk to the patient during testing procedures. Let us see an overview of the parts and their assembly.

It is not an AP nor an APG device (according to the EN 60 601-1 definitions). You must follow all the cleaning procedures in System Maintenance, and you must thoroughly inspect the components after cleaning and before each patient test. It is necessary to make the PC, connected to the Pony FX, compliant with EN. Any Mouse and Printer compatible with the MS Windows operative system. In the right group there are 10 alphanumeric keys, the confirm and the delete keys.

Attempting to defeat the proper connection of the ground wire is dangerous for users and equipment. When the installation is over, the program will advise you with a message indicating that the installation has been successfully completed, click on, To move the cursor among fields, press the, To move the cursor among fields, move the mouse on the desired field and, Upload manuals that we do not have and get.

The bronchial provocation tests must be executed according to the doctors discretion. 1.In the Windows Start menu, open the Program Group in which the software was installed. A more detailed description of the keys functions, of the keyboard logics and of the menus, see the chapter Using Pony FX. Contraindications for the Spirometer tests. Pony FX has a keyboard (see the next picture), which allows the user to interact with the device. For further details, see the chapter Database management. For ex. Post-operating state from thoracic surgery For FVC tests: Severe instability of the airways (such as a destructive bronchial emphysema), Bronchial non-specific marked hypersensitivity, Serious problems for the gas exchange (total or partial respiratory insufficiency). Actually non recommended accessories can affect safety unfavourable. 8.In accordance with their intended use Pony FX is not to be handled together with other medical devices unless it is clearly declared by the manufacturer itself. 1.To run the software, double click on the icon Registration or select Registration from ? Please contact the technical support. Connector for the RS232 cable, if the PC doesnt have an USB port, or for the oxymeter (option). The led switches to green after some time of charging. 1.This user manual is to be considered as a part of the medical device and should always be kept on hand. * Other battery charger with different plugs (Australia, UK, USA) available on request. PC conform to European Directive 89/336 EMC. Cardiopulmonary resuscitation emergency equipment accessible. Select Toolbar from Options menu in order to show or hide the toolbar. The air passing through the helical conveyors, takes a spiral motion which causes the rotation of the turbine rotor. It is disposable, and measures the flow detecting the difference of pressure at the two sides of a membrane. Device not suitable in the presence of flammable anaesthetics; To run the software, double click on the icon.

Leader mondial, crateur de solutions compltes pour le test deffort cardio-pulmonaire, la calorimtrie indirecte, la composition corporelle, Italy (HQ) | USA | United Kingdom | Germany | France | Denmark | Switzerland | The Netherlands | Australia | Hong Kong, 1996-2022 COSMED srl| Terms and Conditions | Legal Information | Privacy | Cookie, REMARQUE ! Cosmed equipment are not AP not APG devices (according to EN 60601-1): they are not suitable for use in presence of flammable anaesthetic mixtures with air, oxygen or nitrogen protoxide. Click on the OK button with the Left button of the mouse to confirm the information input on the dialog box or click on Cancel button to cancel changes.

The modern standard processes have been revealing secure in several clinical studies. If the PC connected to the Pony FX is placed within the patient area (according to the IEC 60601-1-1 norm), the PC has to be made compliant with the IEC 60601-1-1 norm by means of an isolation transformer. For MVV test: Contraindications for Bronchial provocation tests. The main elements a user can detect in the Pony FX unit are the following: Some connectors on the bottom side of the device. Before using non recommended accessories it is necessary to get in touch with the manufacturer; ordinary equipment maintenance, inspections, disinfection and cleaning are performed in the way and with the frequency described; any modification or fixing is carried out by qualified personnel; the environmental conditions and the electrical plants where the device operates are in compliance with the specifications of the manual and the present regulations concerning electrical plants. Very low battery, because of the unit has been not used for a long time. Afin de vous offrir une service optimal, ce site utilise des cookies. Device not suitable in the presence of flammable anaesthetics; The system meets the EMC Directive 89/336, EN 55011 Class B (emission), IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4, UNI EN ISO 9001:2000 (Registration n 387-A Cermet). Some connectors on the bottom side of the device. The Pony FX can be directly connected to an external printer in order to print the performed tests on a different paper.

Other international references have been followed when these were not available. Bronchial obstruction caused by the respiratory manoeuvre. Before operating the Pony FX system we strongly recommend to check the equipment and register you as a customer. Note: Some parameters are computed only by the PC software. 6.This device is not suitable for use in presence of flammable anaesthetics. Cardiopulmonary resuscitation emergency equipment accessible. No parts of this manual may be reproduced or transmitted in any form without the express permission of COSMED Srl. The typical operating environment of Microsoft Windows is the Dialog box. The precautions reported below are of fundamental importance to assure the safety of all COSMED equipment users. The red led should switch off when the temperature falls again in the range 5-45C. Before using non recommended accessories it is necessary to get in touch with the manufacturer; ordinary equipment maintenance, inspections, disinfection and cleaning are performed in the way and with the frequency described; any modification or fixing is carried out by qualified personnel; the environmental conditions and the electrical plants where the device operates are in compliance with the specifications of the manual and the present regulations concerning electrical plants.

2.Type the requested information and click Send to send the form via e-mail to COSMED. Please fully charge the unit. Positioning the mouse cursor on one of the buttons of the toolbar (if the option Hints is enabled), the description of the corresponding function is shown in a label.

There are not data that reveal specific contraindication for the bronchial provocation test through inhalation. Le logiciel innovant OMNIA pour l'archivage, la gestion et l'interprtation des tests est fourni. Actually non recommended accessories can affect safety unfavourable. Recent infection in the superior air tracts. Very low battery, because of the unit has been not used for a long time. Bronchial obstruction caused by the respiratory manoeuvre. In particular grounding reliability and leakage current suppression can only be assured when the device three wire receptacle is connected to a yellow - green return connected to earth ground. For ex. non respect of the hereunder reported precautions and instructions. If you have any complain, feedback information or suggestion, please inform us at complain@cosmed.it.

Internally powered equipment type BF device (used stand alone), class II type BF device (used connected to mains), Protection against water penetration: IP00, ordinary equipment unprotected against water penetration. shows the button to click in the software to activate the related feature. Before powering the system, check the power cables and the plugs. If the form is not enclosed in the packaging, please contact directly COSMED. pregnancy with complications at the 3rd month. Si vous ne changez pas les paramtres de votre navigateur, vous tes d'accord En savoir plus. Please contact the technical support. The present handbook has been developed with respect of the European Medical Device Directive requirements which sort Pony FX within Class II a.

The active window is highlighted with a different colour of the caption. Any Mouse and Printer compatible with the MS Windows operative system. Excel is a registered trademark of Microsoft Corporation. 7.Keep the device away from heat and flame source, flammable or inflammable liquids or gases and explosive atmospheres.

The first time the software is used, it is necessary to configure the communication port with the PC (USB, COM1, COM2,). 6.When the installation is over, the program will advise you with a message indicating that the installation has been successfully completed, click on End.

Predicted value FEV1 less than 1.51 in men and predicted value FEV1 in women less than 1.21. Notice: The software is copy-protected. Avec un grand cran LCD couleur et une imprimante thermique intgre, vous pouvez excuter des tests sans avoir besoin d'un ordinateur. Together with the PC software, a registration software is supplied. 4.The battery charger sold with Pony FX must be used only to re-charge the battery. Damaged electrical parts must be replaced immediately by authorised personnel. However it is recommendable to respect the following contraindications: Serious bronchial obstruction (FEV1 in adults).

Manualzz provides technical documentation library and question & answer platform.Its a community-based project which helps to repair anything. With this software it is possible to fill in an electronic form with the customer information. Battery temperature >45C. The led switches to green after some time of charging. For further information, please refer to the enclosed registration and warranty form. Temperature range 10C (50F) and 40C (104F). It is to be used by physicians or by trained personnel on a physician responsibility. The USB connection works properly only with Windows XP.

11.Graphical symbols used in accordance to present specifications are described here below: The physical strain to execute the respiratory manoeuvre is contraindicated in case of some symptoms or pathology. It is connected to the unit connecting the two tubes to the P+ e P- connectors. If the PC does not have an USB port, it is possible to use a RS232 serial connection. In case of missing or damaged parts, please contact Cosmed technical assistance. For any information you may need, please contact the manufacturer directly at the following address: Via dei Piani di Monte Savello, 37 P.O. These are the typographic keynotes used in the manual. Connector for the turbine flowmeter or for the airway resistance measurement module (option). The PC is connected to the Pony FX unit, through an USB connection, to the USB port with the symbol by side. VC/IVC - Slow Vital Capacity and Ventilatory pattern, % Fall in FEV1 from baseline or post diluent, Provocative dose causing FEV1 to fall 10%, Provocative dose causing FEV1 to fall 15%, Provocative dose causing FEV1 to fall 20%, Flowmeter (pneumotachograph or turbine, depending on the version).



Sitemap 26