We have had to call the sewer system 3 times to come out and fix our grinder pump. (May 25, 2015) Judy said:Having constant problems with septic pump grinding system. I can't believe the pump has failed after only 2.5 months, it's unbelievable. Sewage ejector pumps range from around $300. Replacing the whole pump might follow if the switch replacement didn't work. The basins have the same capacities, but the Pro380 basins are shorter so less digging and a shallower burial is required in difficult soil environments such as clay or bedrock. sewage x24 liberty pumps hp pump iron cast system

When connected to the CFGCI outlet, it did NOT produce the same noise.

The basin in shorter and wider instead of taller and narrower; its 24 inches tall instead of 30 inches and 27-5/8 inches across at its widest point instead of 24-1/2. I'd look for a sewer line blockage first.

It wasn't fine.

Its basically the P372LE51 in a shorter and wider basin. Brendon: contact the manufacturer or their service rep for your pump. Can you recommend a sealant that can be used to caulk around the outside of the lid that will adhere to both the concrete of the floor and the metal of the lid? Are they telling you that just sitting in the box, not having been touched by a human being, their product deteriorates? On 2019-09-08 by (mod) - new grinder pump went out within 15 months. liberty pumps sewage system

Zoeller 105-0001 Laundry Pump Package (including M53) Review: The Best Drain Pump for Dishwashers, Laundry, and Garbage Disposals? It appeared to be clogged, but plunging it did nothing, so I checked the pump and it's not functional at all. We had a plumber come out today and look at the issue with the Liberty Pro 380 series grinder pump in our basement. An automatic mechanical wide angle float switch is included and the pump uses a 2 inch FNPT discharge. At the break, a flow of waste water and sand/gravel was feeding into the tank until the point that about 10 feet of the drain pipe (still connected to the tank) was filled solid with sand and gravel. thanks- I had a new pump float put in,, new pump. Drive it a while and it'll be fine."

if those steps don't fix the trouble, try replacing the switch.

Is there evidence of damage or malfunction in the pump itself or switch or controls etc.Signs of malfunction besides simply not running when it should might be missing check valve(s), flow back into the tank, clogging, tipping over, or tank flooding. We have an ejector system, sump pump and septic tank. Thank you. Liberty Pumps P382LE41 Pro380 Sewage Pump System Review and P382LE51 Comparison, Liberty Pumps P382LE51 Pro380 Sewage Pump System Review and P372LE51 Comparison, Liberty Pumps P372LE41 Pro370 Sewage Pump System Review and P372LE51 Comparison, Liberty Pumps P372LE51 Pro370 Sewage Pump System Review. I have a shower and my laundry room in the basement as well. It can pass 2 inch solids and runs on 115 volts single phase AC at 12 amps with 22.5 locked rotor amps. A couple of weeks ago we started hearing water run through the pipes in the main bathroom when we flush the toilet. We have a duplex Liberty grinder sewge pump system and the basin located inside a "finished" basement.

Thanks for the information! I'd replace it.

If questions 1 or 2 cite defects, what's the proper repair. I truly appreciate your knowledge and advice here. Continue reading at SEWAGE EJECTOR / GRINDER PUMPS - topic home, or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below. Now I have to do a huge sewer pump repair and with little experience. I have a sewer pump that pumps from my septic tank to city sewer. 1. LASAA Should Protect OOH Investments MIPAN President, Nigerian Breweries Organizes Free Training On Employability and Digital Skills For Youths, VIDEO: Maltina Encourages Lagosians to Explore Water Transportation, I Got In A Lot Of Trouble, I Had To Leave Nigeria Davido. Practically speaking, it does everything the P372LE51 does except in a squatter package, which means less vertical digging and a cheaper installation in an environment with bedrock, clay, or other difficult soil conditions. The gravel-clogged pipe needs to be cleared or removed and replaced or the system will surely not work properly.

My little daughter was playing with the toilet and accidentally flush a huge amount of paper and crayons. (Apr 26, 2015) steven buonomo said:What is a good price to funish and install a 2hp ejector/grinder pump ? We have no relationship with advertisers, products, or services discussed at this website. On 2020-03-11 b What type of battery do you recommend for use in the Model 441 (battery back-up sump pump)?

Sometimes we come across someone who makes up nonsense for whatever reason. Typically a sump pump is used in a basement or crawl area de-watering system. A detailed reply to this question is at SEWAGE PUMP DAMAGE & REPAIR.

Is this right?? Tampons, dental floss, high levels of powdered laundry detergent, kitty litter, string, are examples of stuff that can do damage. The primary bonuses of the system include the QuickTree approach, which allows you to reach, pull, and replace the float switch via the top of the basin without disturbing neither the pump nor the plumbing, and the basin itself. So I told him to take a 5 minute break, and I threw on some rubber gloves and less than 30 seconds later a single paper towel was removed the impeller. For example an effluent pump won't last long if asked to pump solid waste. If so that doesn't sound good to me.I can't diagnose the actual failure of your grinder pump from your brief text - as I don't know what failed; surely if your sewer line is blocked you'd know that because no pump would push any waste out of the grinder reservoir.Watch out: a common cause of sewage pump failure is selection of the wrong pump type - one that is unable to handle the type of waste or debris it encounters; related is the mistake of flushing dental floss, sanitary napkins, tampons into the grinder pump system. Septic Pump Alarms. Any ideas? This may have been happening for a couple of weeks without our knowledge until the water backed up. Everyone does the same thing with the same resultsany ideas? There is perhaps a wiring error, short circuit, wet connections, or a seized pump motor that needs to be found and repaired. How is it possible? Sewage Ejector Pump vs Sewage Grinder Pump: Which is Better for a Home or Small Business? It's like the pump float isn't telling the pump to come on when it should no one can seem to figure out why the alarm keep coming on . What is the best type of pump to use in my application? Should I add a high-level alarm to my system? An ejector pump is designed to pump only clarified effluent - that is, liquid, NOT solids. by Doug

It is connected to my downstairs bathroom, and no smell coming from downstairs just the kitchen sink. Knowing the pump model we can both check the IO manual for your pump for further de-bugging help.EG.

- Sewage Pump Repair Success: jammed Liberty Pro 380 Grinder Pump.

(Apr 19, 2016) Diane said:I have an ejector pump in the basement where my parent say. However, if your pump starts but wont pump, you might also need more head than what your pump can give. Hi, Two years ago we installed a full bath by our pool. If you find our work at PumpThatSump helpful, you can put our relentless reviewing of every pump and fixture on the market to the test by shopping via our links above for whatever you need to make your house a home. July 30, 2015) sly said:got a sewage pump from lows for my basement the toilet keep backing up did I get the right pump. He told me that this voided any warranty, and that I needed an entirely new pump installed because the paper towel was coiled all around the inside of the motor and could be taken out. When the pump quits pumping, some liquid flows back thru the check valve causing us to hear the water hammer. It's a variation on the OPM problem: spending other people's money to reduce your risk, explained at https://inspectapedia.com/home_inspection/Other_Peoples_Money.phpIn my opinion, if you hate doing a job, don't try it as you'll be sorry, make a mess, and maybe incur avoidable costs.But if you're interested in giving it a shot, and if you can read instructions, work carefully (e.g.

3. Are they telling you that just sitting in the box, not having been touched by a human being, their product deteriorates? The 4 inch plastic pipe leading to the larger sewer line was replaced with a 6 inch pipe with two clean out places. How to correct this? I can't make sense of what he told you. How can we fix this? B. Email: Julie @baxter-mason.com regarding water hammer due to a septic lift station. Please educate me. (Dec 6, 2015) Shelley said:my husband works as a installer of insulation in commercial building. I'd have asked the service tech at your sewer pump to "show me the grease". Here's a photo of the Liberty Pro380 grinder pump unit [shown above], if helpful. Now the grinder pump is turning on and off every fifteen seconds even when no water is being used in the house. We have had a master plumber out, added a Oatey sure-vent, and have checked the venting.

We have a lot of vapour and smell which seems to be escaping through the lid which will not sit properly on top of the basin . If the grinder / lift pump from the outdoor bath was previously working successfully having been connected to your existing house DWV system then it was fine.2. This gives a good explanation of what a sewage pump is used for. confirm that the circuit powering the pump is still on at the panel and where the pump is connected2. I have a 20 year old ejector pump in my finished basement. Septic pumper trucks have tremendous vacuum and should have no trouble picking up solids and debris from the tank. What are some of the solutions for pumping the sewage up to the sewer or septic tank? Should I manually fill it, use Rid Ex and unplug? My question is can over a period of time this polyester insulation he is covered in everyday cause our masarator to break from being clogged up? Solid laundry detergents can form soapy blobs that clog drains or pumps; I'd go back to liquid detergent and perhaps experiment with different brands if you don't like how the detergent smells. I know it comes on because the pump isn't coming on to pump out the water and it get too high, pump float line not tangled up w/anything, if I lift the pump float the pump does come on, checked opening on pump not plugged ---very frustrating. Thanks for any suggestions you can give me. We do not pour grease down the drain, have mesh traps in the sink so food can't really go down the drain.Is this normal? Sometimes the first few flushes are simply filling the waste pipe up to a point of blockage that is a bit far down the line.

An intermittent blockage of the float switch - watch the pump through several cycles to be very sure that nothing is impinging on the float movement. (Aug 23, 2015) Betsy said:Septic pump not pumping water out pump does work line to drain field not clogged new pump float septic pumped out last month septic alarm keeps coming on, if I open pit where pump is and move the float pump does come on and starts pumping water out.

On 2020-05-22 - by (mod) - pump makes a thumping noise, Perhaps water hammer at a noisy check valve.But also look for a loose pump that's rotating at start and stop.

4. check that the type and model of pump is properly-matched to how yours is being used. Is a grinder ejector pump effective in preventing tampons and other feminine products from clogging the pump?

You may want to use one of the national test labs such as EMS.

JeffJeff: to check out the operation of the check valve on a sewage pumpListen for drain-back when the pump stops running. This seemed odd to me because this unit is 2 months old and the float looked fine to me. John said:Are chemicals used in sewage pump systems to dissolve solid waste?

for complete details. There was a slight crack in the lid of the ejector pump but we caulked it. Thanks. Linda, On 2019-01-14 by (mod) - whether or not a sewage pump can handle tampons and sanitary napkins and wet wipes, TonyThe answer of whether or not a sewage pump can handle tampons and sanitary napkins and wet wipes is model dependent.Generally you should keep such products out of toilets and sewage pumps as they risk pump clogging and damage. I am more concerned about the sand/gravel in the tank and the life expectancy of the pump. If so that doesn't sound good to me.I can't diagnose the actual failure of your grinder pump from your brief text - as I don't know what failed; surely if your sewer line is blocked you'd know that because no pump would push any waste out of the grinder reservoir.Watch out: a common cause of sewage pump failure is selection of the wrong pump type - one that is unable to handle the type of waste or debris it encounters; related is the mistake of flushing dental floss, sanitary napkins, tampons into the grinder pump system. Thanks for the information!

Are there any recomendations for what type of TP is best to prevent these types of problems?

These questions and replies were posted originally at SEWAGE EJECTOR / GRINDER PUMPS - home - be sure to review that article. avoiding getting electrocuted or developing a septic infection), at the end of the day, in my experience, you may have to buy an expensive tool that you use only once, wreck entire sub-assemblies and have to replace them, hurt yourself doing the job, and make a mess, but, at the end of the day, if you work carefully, you may have better success than if you'd hired someone as ignorant as you but who also didn't give a darn about the quality of the job.PS: know when to stop and when to call an expert. What is the difference between a sewage pump and a grinder pump?

He cleaned the tank, said the shifting tank was fixed, charged us and we paid. Speaking correctly. Thermal overload protection in the motor occurs at 221F while liquids will be pumped at up to 140F. Subscribe my Newsletter for new blog posts, tips & new photos. I have A Liberty 380 and the discharge connection where it connects in the cover is spraying out inside the basin while discharging? (Which you can't do with a toilet or the drywell clogs quickly). Perhaps you have a failed or leaking check valve on the outlet from the grinder pump. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. For completeness, a "sump pump" is intended to pump only water, such as groundwater seeping under a basement floor slab up to a groundwater disposal system such as a pipe that discharges to an approved storm drain (not allowed in some jurisdictions) or to a drywell, or to an area of surface runoff. Also check for leaks in the vent system for the grinder pump. On 2019-09-14 by (mod) - grinder pump runs more frequently lately.

Your ability to pull the float switch if it goes bad without affecting the pump or plumbing also increases the systems lifespan and ease of maintenance. Is that normal?

He then quoted me $10k.Is this true.that a lift station/grinder should NOT be hooked into your house DWV system? Any suggestions. Compared to the PRG101A, the P382LE51 is faster, cheaper, and comes with a basin. Zoeller 507-0011 Pro Pak 98 Pre-Assembled Backup Sump Pump Review, Zoeller 508-0007 Aquanot 508 ProPak 98 Pre-Assembled Sump Pump Review, Zoeller 508-0006 Aquanot 508 ProPack 53 Pre-Assembled Sump Pump Review: High Reliability for $500, Zoeller 507-0008 Pre-Assembled Sump Pump Review: A Top Battery Backup System For $500, Wayne WSSM40V Pre-Assembled Combination Sump Pump Review: The Best Battery Backup System Under $600. They have a slow drain in the bathroom, can we use draino, baking soda, baking powder?

Thank you for your quick reply. We discuss sewage grinder pump types, sizes, voltages, horsepower, installation and maintenance. You can buy a silent 2 inch check valve here. I would look for a failed check valve that allows sewage backflow into the pump or a failed pump control switch, relay, or float.

Our forensic lab is on special assignment. My grinder pump runs more frequently lately. Help please! The problem continues. What should we know when asking someone to look at the pump for damage?It is only 3 weeks old and we want to make sure it is in new working condition. check that the type and model of pump is properly-matched to how yours is being used. People often mix up or use these terms interchangably and in error, even some plumbers. Or open the pump chamber and watch what happens at the end of a pump-on cycle.

What we don't know is how long a screaming pump with bad bearings will continue to shriek before it stops. We have had loads of sand and gravel going through the system now. The only separation from it is a box built from 1/2" press board. Ground sewage slurry breaks down just the same as regular sewage, though most-likely faster and more easily. KevinThank you very much for the follow-up as that will certainly help other readers. Check also that there is no blockage of the float switch or binding of the pump impeller from dental floss or qtips or other crud. If you watch the pump float switch and it moves up when wastewater rises in the sump pit but if the switch doesn't turn on the pump I'd replace it.



Sitemap 0