pumptec plus franklin phase protection single system Avoid the common mistake of adjusting the regulator bypass pressure higher to compensate for lower spray pressure. A good diagnostic practice is to replace the pressure gauge with a known good gauge as a check. pumptec After extended use or pumping abrasive fluids, the plungers can become grooved, damaging the seal. To prevent seal damage, avoid: During reassembly, an O-ring can slip out and become pinched permitting water to leak out. You will be contacted before shipment should that be the case. It should not have much if any by-pass while you have the spray gun open. Pumptec-Plus protects against a variety of fault conditions. pumptec protection pump dry run franklin 3hp 2hp Should be at least 12 volts. 43/4 hp flint & walling submersible pumps water well pumps and related accessories, GotMultiple Questions?Please Submit Them On This Form, HOME VIEW YOUR CART POLICIES, Franklin Pumptec Plus Pump Protection Control Box, May Be Used On Other Brands Of Motors Including Above Ground Applications, For installations up to 5 hp.

Pumptec interrupts power to the motor whenever the load drops quickly or below a preset level. It monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Additional features Easily Adjustable Sensitivity Settings Run and Fault Indicator Lights Heavy Duty Relay Alarm Circuit Contacts UL/CSA Listed$ 270.00. The small pits in a valve disc or seat will allow small amounts of fluid to leak during each compression stroke and result in less flow going out the nozzle. Pumptec pumps are designed and manufactured to withstand rugged use and last for years.

The leakage would need to be substantial to noticeably affect performance. Causes of worn seals include wear over time, lack of proper maintenance, abrasive fluids and excessive heat.

Most Pumptec pumps have stainless steel plungers standard. 700 McKinley StreetAnoka, MN 55303Phone: (763) 433-0303Fax: (763) 433-0404Toll Free Fax: (888) PUMPTEC.

Spray PSI is too close to the by-pass PSI of the Unloader. Check battery voltage and charge as needed. Check and clean hoses and make sure the tank has no sludge in the bottom. Protects Pumps From, Dry Well, Dead Heading, Overcurrent, Overvoltage and Undervoltage. When excessively high temperature fluids are run through the pump, the seals and elastomers can become deformed and fail. Pumptec packages plungers and seals together in kits because they should be replaced at the same time. Pumptec-Plus protects against a variety of fault conditions. is a microcomputer-based pump protection device. Reinforced flexible hose should be installed on the pump inlet, Properly seal all connections with PTFE tape or sealant for sealed connections, Confirm your liquid temperature is within the maximum limits of the pump, less than 140F, Connect the supply line from supply tank to the pump above tank bottom to avoid picking up any settled debris, The pump supply line from the tank should be plumbed from the opposite side of the tank than where the bypass return is located. The debris-damaged or worn seals in an unloader can allow fluid to leak out the by-pass, decreasing performance. The Informerdisplays 16 parameters including calibration point, trip point, running points, and last fault. Check and repair any loose or cracked fittings. Leak in high pressure hose or connections. Push button Snap ShotTM calibration makes Pumptec-Plus simple to install and an effective troubleshooting tool. Check current flow from the battery, circuit breaker tripped, fuse blown, 12 volts after the breaker, 12 volts after the switch, and 12 volts at the motor. This will minimize air bubbles caused by agitation being drawn into the pump, Check the seal of the in-line filter because this can degrade and lose its seal over time. To avoid starving the pump: Verify all valves are open in the supply line before starting your pump, Check for line restrictions and minimize plumbing fittings like elbows, Verify the inlet line is at least the size of the pump inlet port, ideally one size larger, Avoid Rigid Plumbing.

Also check the ground wire and ground stud for good connection. Indicator lights on the cover provide complete system status. When the timer counts to zero or power is removedand reapplied, the SPP reactivates its output relay and turns the pump back on. Make sure water is flowing at the pump. Use these pump troubleshooting tips to pinpoint and correct potential issues.

Run and fault lights on the cover make diagnosis quick and easy. The erosion resulting from high-pressure water is powerful and will increase nozzle size, which will result in lower pressure over time. Abrasives in solution have damaged pump seals. Operational conditions or other external factors like clogged nozzles or filters, worn seals, or pinched hoses may diminish performance over time. As the pump operates, the valves can begin to degrade from exposure to chemicals, heat, cavitation, and abrasives. Pumptec is a microcomputer-based pump protection device. It monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. If increasing adjustment does not increase spray pressure, then replace the nozzle. single-phase protectors include a unique microcontroller-based voltage and current-sensing circuit that constantly monitors the incoming power for fluctuations including overcurrent and undercurrent. Replace nozzle with new one of same size.

Run and fault lights on the cover make diagnosis quick and easy.

The most common cause for low performance is worn nozzles. Examine valves and clean or replace as necessary.

Additional features: Push Button Calibration Run and Fault Indicator Lights Heavy Duty (30A) Contactor Works with PSC, Split-phase CSCR and CSIR motors UL/CSA Listed, For 2- & 3-wire single-phase motors, 1/3 to 1.5 hp. Occasionally pressure gauges can become fatigued and damaged causing malfunction. Replace bad components. solid state pump protection system is designed for 1/2 to 5 hp single-phase submersible pump motors. The SPP then begins itsuser-selectable restart delay (dry-well recovery) timer. Check the by-pass flow when you are spraying. The SPP-111P-3RL, SPP-233P & SPP-235P single-phase protectors include a unique microcontroller-based voltage and current-sensing circuit that constantly monitors the incoming power for fluctuations including overcurrent and undercurrent. Indicator lights on the cover provide complete system status. Pumptec interrupts power to the motor whenever the load drops quickly or below a preset level. The primary causes of water leakage are worn seals. Be sure you always have adequate amounts of fluid available to the pump. The SPPsare all mounted in a NEMA 3R enclosure.

Pumptec recommends that nozzles made from hard materials, not brass, should be used with our pumps. Pumptecs seal designs will reveal worn seals in the form of drips below the pump. The integrity of connections needs to be maintained over time and this may require periodic inspection. 13.2 volts is considered full charged. Either use a larger nozzle or if AMPS allow, adjust pressure up or use a stronger unloader spring. The Pumptec-Plus solid state pump protection system is designed for 1/2 to 5 hp single-phase submersible pump motors. Mix chemical thoroughly and improve filtration. Examine by-pass hose for pinch spots and make sure it is large enough, generally 1/2" to 3/4". Proper care must be taken to not exceed 140F fluid temperature in the pump at any time, including idle time. Look for leaks from cracks in hoses or from fitting connections. Insufficient fluid supply, or starving, to the pump inlet is one of many causes of low pressure. It is important to monitor pump systems to determine causes of wear and fix them. Due to rapidly changing commodity market conditions, published pricing may change without notice. When an abnormality, such as loss of suction, is detected,the control deactivates its output relay and directly disconnects the pump motor.

Push button Snap ShotTM calibration makes Pumptec-Plus simple to install and an effective troubleshooting tool. This primary flow control device can be harmed from debris in the fluid or simply worn out from use. When an abnormality, such as loss of suction, is detected. If you have 12 volts at the motor, the motor is bad or needs brushes. Franklin Pumptec Pump Protection Control Box. Plungers with grooving are not reusable and need to be replaced. An infrared LED communicates directly with a handheld diagnostic tool called the Informer (sold separately). Operating the pump without any fluid can increase seal temperature and damage seals. If you are seeing a lot of by-pass, back off the regulator pressure to clean or install a repair kit in the regulator. A preventative maintenance schedule needs to be followed, especially when using harsh or abrasive chemicals. Replace with new plunger and seals.

It is typically necessary to replace a pinched O-ring because they become misshapen and will not seal properly afterward. Protects Pumps From, Dry Well, Dead Heading, Overcurrent, Overvoltage and Undervoltage.

Pinched hoses and clogged filters will starve the pump of fluid and damage seals as a result of excessive vacuum.