Store sheets under cover and keep dry prior to installing. Butt joints must not fall within 4 inches (102 mm) of a stud.
Texas Department of Insurance Product Evaluation EC-23.
Wood Framing: 0.089 inch (2.2 mm) shank by 0.221 inch (5.6 mm) head by 2 inches (51 mm) corrosion resistant siding nails. For information on installations above 60 feet, please contact JH technical support. Vertical H Trim: Aluminum extrusion to be used along vertical butt joints. Hardie Architectural Panels for 30 years. Type: Smooth vented, 16 inches (406 mm) by 12 feet (3658 mm). Protect edges and corners from chipping. Factory Finish Touch Up: Apply touch up paint to cut edges in accordance with manufacturer's printed instructions. ! Protect installed products until completion of project. Minimum standard panel design size is 12 x 16 inches (). x 3.5 in. Type: Textured Cedarmill, 16 inches (406 mm) by 12 feet (3658 mm).
CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Product: 5/4 NT3 Boards, 3-1/2 inch (89 mm) width.
Type: Select Cedarmill 7-1/4 inches (184 mm) with 6 inches (152 mm) exposure. Repair any punctures or tears in the water-resistive barrier prior to the installation of the siding. Water Tightness: No drop formation; Pass. Panels may be installed as soffit or ceiling over wood or steel framing; 20 gauge (33 mils) minimum to 16 gauge (54 mils), complying with local building code. Factory Primer: Provide factory applied universal primer. Type: Hardie Architectural Knockdown Panel 4 by 10 feet (1219 by 3048 mm). Metal Framing: 1.5 inch (38 mm) [AGS-100] .100 inches by 25 inches (2540 mm by 635 mm) ETandF Pin or equivalent pneumatic fastener. Workmanship Warranty: Application limited warranty for 2 years. Factory applied finish by fiber cement manufacturer in a controlled environment within the fiber cement manufacturer's own facility utilizing a multi-coat, heat cured finish within one manufacturing process. Figure 28 BAND BOARD A ashing is required over the trim and Flat Tabs. For further information, refer, to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE (1-800-942-7343). Loss Percentage: Less than or equal to 3.0 percent; Pass.. Freeze/Thaw, percent strength retention: Greater than or equal to 80 percent; Pass. Installed on flat vertical wall applications only. HardiePlank HZ10 lap siding, HardiePanel HZ10 vertical siding, HardieSoffit HZ10 panels and HardieShingle HZ10 siding requirement for materials: Fiber-cement siding - complies with ASTM C 1186 Type A Grade II. 4/4, 5/4 Boards EFFECTIVE SEPTEMBER 2013 Visit www.jameshardie.com for the most recent version.
Soffit Panels: HardieSoffit HZ10 Non-Vented Soffit Panel, as manufactured by James Hardie Building Products, Inc. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturers written instructions. Figure 13 Figure 14 Soffit panel 2x sub fascia HardieTrim fascia/rake HardieTrim rake trim HardieTrim frieze board HardieTrim frieze board flashing HardieTrim band board leave a minimum 1/8" gap, then caulk.
Class A Material: Per FBC 2017 and 2020, and 2018 IBC Section 803.1.1 Surface Burning Characteristics when tested in accordance with ASTM E84: Flame Spread Index : 0. Type: Sierra 8 inches (203 mm) Vertical siding panel 4 feet by 8 feet (1219 mm by 2438 mm).
Type: Smooth, 16 inches (406 mm) by 12 feet (3658 mm). Type: HardieShingle Individual Shingles 12 inches (305 mm) wide by 18 inches (457 mm) high with 8 inches (203 mm) exposure.
If large areas require touch-up, replace the damaged area with new pre-finished siding. Some studies suggest, smoking may increase these risks. !
90 percent drainage efficiency shall be used. Type: Cedarmill Vertical siding panel 4 feet by 8 feet (1219 mm by 2438 mm). 13 y 14). Fiber cement lap siding, panels, shingle, trim, fascia, moulding, and accessories; James Hardie HZ10 Engineered for Climate Siding and Hardie Architectural Panels. Base Jointer: To be used to connect Base trims.
Artisan HZ10 lap siding requirement for Materials: Fiber-cement Siding - complies with ASTM E 84 Flame Spread Index = 0, Smoke Developed Index = 5. Figura 13 Figura 14 Panel Soffit 2 subimpostas Imposta/moldura inclinada HardieTrim Moldura inclinada HardieTrim Friso Hardie Trim proteccin Friso HardieTrim Tablero de banda HardieTrim deje un espacio de al menos 1/8", despus aplique masilla. penetration and junction flashing in accordance with local building code requirements. Match touch up color to siding color through use of manufacturer's branded touch-up kits. Type: Shiplap 10-1/4 inches (260 mm) with 9 inches (229 mm) exposure. Length: Plus or minus 0.5 percent or plus or minus1/4 inch (6 mm). Equilibrium Conditioned, psi: Greater than 1450 psi (10 MPa); Pass.
Wood Framing: No. Texas Department of Insurance Product Evaluation EC-55.
Product: 4/4 NT3 Boards, 7-1/4 inch (184 mm) width. The first sections of this manual provide a general product description and information about safe practices, and proper 2 19 Air Conditioners, Service Panels and Other Wall Mounted Devices 19 Butting to Mortar or Masonry 19 Clearances 20 Siding to Ground Clearance 20 Siding to Flashing Clearance 20 Siding and Trim to Solid Surfaces 21-23 Clearance Requirement Examples 24 GENERAL FASTENER REQUIREMENTS 24 Pneumatic Fastening 25 FINISHING 25 Finishing James Hardie Siding and Trim Products 25 ColorPlus Touch-Up 26 ColorPlus Products with Protective Laminate Sheet 26 Caulk 26 Repair Patching 26 Back Priming/Back Sealing 26 Maintenance 27 HardieWrap PRODUCTS DESCRIPTION 28 INSTALLATION OF HARDIE WRAPS 29 3 43 Window and Door Trim 44 INSTALLATION OF 4/4, 7/16 HARDIETRIM BOARD 44 Nailing 4/4, 7/16 HardieTrim board 44 Frieze from 4/4, 7/16 HardieTrim board 44 Installing Rake and Fascia Board 45 Drip Edge 45 4/4, 7/16 HardieTrim board Fastener Specifications 46 INSTALLATION OF HARDIETRIM BATTENS 46 Getting Started 46 HardieTrim Battens Fastener Specifications 47 Horizontal Joint Treatment 48-51 HardieTrim HZ10 Battens Installation Requirements 52-55 HardieTrim HZ Battens Installation Requirements 56-59 7/16, 4/4 and 5/4 HardieTrim HZ10 board Installation Requirements 60-63 7/16, 4/4 and 4 If stored outside protect with an additional waterproof covering.
6, 7 and 8 in National Evaluation Service Report No.
90-100, Products Installation Guide_HardiePlank pg. in the first 10 ft. Do not use Hardie Architectural Panels in Fascia or Trim applications. Allow 1/8 inch gap between trim and siding.
Type: Select Cedarmill 12 inches (305 mm) with 10-3/4 inches (273 mm) exposure. If framing preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. Type: Select Cedarmill 5-1/4 inches (133 mm) with 4 inches (102 mm) exposure. Product: ColorPlus Technology by James Hardie. J Trim: Aluminum extrusion to be used as a trim at abutments; soffits, masonry, windows, etc.
Minimum 1-1/2 inches (38 mm) face and straight, true, of uniform dimensions and properly aligned. CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. Tested in Accordance with ASTM E136: Classified as non-combustible. INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. Use weather cuts sloped away from the wall to join (fig. Install metal Z flashing and provide a 1/4 inch (6 mm) gap at horizontal panel joints. Wood Framing: 6d common corrosion resistant nails.
Table R703.3(1): 2009, 2012, 2015, and 2018. 78-89, Products Installation Guide_HardieSoffit pg. Metal Framing: 1-1/4 inches (32 mm) No.
Los clavos de acabado deben clavarse al ras de la moldura (il. Low-Profile Inside Corner Trim: Aluminum extrusion to be used for inside corners. Fasteners must penetrate minimum 3/4 inch (19 mm) or full thickness of sheathing. Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6 in. Metal Framing: 1 inch (25 mm) No. Type: Hardie Architectural Multi-Groove Panel 4 by 10 feet (1219 by 3048 mm). Product: 5/4 Boards, 7-1/4 inch (184 mm) width. Physical Observations Mass: No structural alteration; Pass.
Sign in to see pricing and availability which varies by market, Resists cracking and splitting from hot humid summer conditions, Superior performance in high wind and hurricane areas. TRIMMING CORNERS When installing corners or other vertical trim, position boards on the wall and attach (fig. Type: Smooth, 12 inches (305 mm) by 12 feet (3658 mm).
3). Section 05 40 00 - Cold-Formed Metal Framing. 101-107, Products Installation Guide_HardieShingle pg. Product: 5/4 NT3 Boards, 11-1/4 inch (286 mm) width. 4). Type: Beaded 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. Finish warranty includes the coverage for labor and material. Substrate: Install a minimum 7/16 inch (11 mm) thick OSB wall sheathing or equivalent braced walls complying with applicable building codes. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options.
Wet Conditioned, psi: Greater than 1015 psi (7 MPa); Pass.
Some studies suggest smoking may increase these risks. Vertical T Trim: Aluminum extrusion to be used along vertical butt joints. For additional information on HardieWrap W, - NEVER use a circular saw blade that does not carry the HardieBlade, - NEVER dry sweep Use wet suppression or HEPA.
These instructions are also NOT valid in portions of WA, OR, CA, NV, AZ, NM.
ASTM E84: Surface Burning Characteristics. Install over braced wood. Locate splices at least 12 inches (305 mm) away from window and door openings. Note: For maximum protection (i.e. INSTALLATION - HARDIEPLANK HZ10 LAP SIDING, ARTISAN HZ10 LAP SIDING, AND ARTISAN HZ10 LAP SIDING WITH LOCK JOINT SYSTEM. N-95) in accordance with applicable, government regulations and manufacturer instructions to further limit respirable silica exposures.
Trim inside corner with a single board trim both side of corner. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a HardieBlade, and dust-reducing circular saw attached to a HEPA vacuum; (3) warn others in the immediate area; (4) wear a properly-fitted, NIOSH-approved dust mask or respirator (e.g. Follow paint manufacturer's written product recommendation and written application instructions. LENGETAS DE SUJECIN OCULTAS Para aplicaciones en esquinas, tablas de banda, ventanas y puertas: Las tablas HardieTrim pueden ser instaladas con lengetas planas (n de sku JH 280154) y lengetas de esquina (n JH de sku 280155) para brindar una sujecin oculta.
Low Profile 45 degrees Outside Corner Trim: Aluminum extrusion to be used for bay windows. Vented Soffit Panels: HardieSoffit HZ10 VentedPlus Panels. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. 8-18 by 0.323 inch (8.2 mm) head self-drilling, corrosion resistant ribbed buglehead screws. Wind speed design coefficient assumptions per Analytical Method in ASCE 7. ASTM E136 - Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 degrees C. Submit under provisions of Section 01 30 00 - Administrative Requirements. Masonry Walls: Aerico Stud Nail, ET&F ASM No.-144-125, 0.14 inch (3.6 mm) shank by 0.30 inch (7.6 mm) head by 2 inches (51 mm) long corrosion resistant nails. Se recomienda un accesorio de tope en la herramienta neumtica. Product: Batten Boards, 2-1/2 inch (63 mm) width. The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. Never use continuous-edge diamond blades, abrasive discs, or high tooth count circular saw blades 9 Caution: Tools and blades designed to reduce breathable silica do not always result in safe levels by themselves. 66-77, Products Installation Guide_HardieTrim pg. Hardie Architectural Panels as manufactured by James Hardie Building Products, Inc. A non-combustible fiber-cement panel.
touch-up while the laminate sheet is in place. Las esquinas tambin pueden ser prefabricadas (fig. Type: Smooth 7-1/4 inches (184 mm) with 6 inches (152 mm) exposure. Place a Flat Tab at the end of each trim board and one tab every stud at a maximum of 16" o.c. Maintain a minimum 1 inch (25 mm) gap between end caps and siding and trim. Rating Tools Cutting Method Cutting 7 Set up cutting station so that the wind carries dust away from the saw operator. Product Composition: Grade II, Type A, fiber-cement sheets as defined by ASTM C1186. Carry, for damage caused by improper storage and, HardieTrim HZ10 .75 in.
James Hardie does manufacture HardieWrap Weather Barrier, a non-woven non-perforated housewrap, which complies with building code requirements.
Product: 5/4 Boards, 5-1/2 inch (140 mm) width.
Please contact James Hardie or consult with a qualified industrial hygienist if unable to adhere to the recommended cutting instructions. Install flashing around all wall openings. Fiber-cement siding - complies with ASTM E 136 as a noncombustible material. Minimum fastener guide for finish nailing: Store flat and keep dry and covered prior to, may result in shrinkage at butt joints. Shim frieze board as required to align with corner trim.. Fasten through overlapping boards. 24862. Touch-up nicks, scrapes, and nail heads in pre-finished siding using the manufacturer's touch-up kit pen. Type: Smooth Vertical siding panel 4 feet by 8 feet (1219 mm by 2438 mm). 11 gauge 1-1/4 inches (32 mm) corrosion resistant roofing nails.
siding TIP: When handling panel products, manufactured panel carriers or caddies can give workers better control. Type: Texture 5-1/4 inches (133 mm) with 4 inches (102 mm) exposure. Remodel mock-up area as required to produce acceptable work.
Only Flat and Corner Tabs can be used with HardieTrim boards to create a concealed fastening. 8-18 by 0.311 inch (7.9 mm) head self-drilling, corrosion resistant S-12 ribbed buglehead screws. Type: V-Groove 8-1/4 inches (210 mm) with 7 inches (178 mm) exposure. INSTALLATION - HARDIE ARCHITECTURAL PANELS. Type: Stucco Vertical siding panel 4 feet by 9 feet (1219 mm by 2743 mm). Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. When installing horizontally, a WRB with min. Section R703.10.1 as ASTM C 1186 Grade II, Type A Fiber Cement: 2009, 2012, 2015, and 2018.
Base Trim: Aluminum extrusion to be used as a base edge solution. Wood Framing: No. Type: Hardie Architectural Knockdown Panel4 by 12 feet (1219 by 3658 mm). 280155) which provide concealed fastening. See General Fastening Requirements. Minimum 20 gauge (1 mm) 3-5/8 inch (92 mm) C-Stud 16 inches maximum on center or 16 gauge (1.6 mm) 3-5/8 inches (92 mm) C-Stud 24 inches (610 mm) maximum on center metal framing complying with local building codes, including the use of water-resistive barriers and/or vapor barriers where required.
Estas instrucciones son para utilizarse SOLAMENTE con tablas HardieTrim HZ10 y NO SON VLIDAS en los siguientes estados: AK, UT, ID, CO, WY, MT.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results.
HardieTrim HZ10 Fascia boards as manufactured by James Hardie Building Products, Inc. Artisan HZ10 Accent trim as manufactured by James Hardie Building Products, Inc. Fiber-cement trim - complies with ASTM C 1186 Type A Grade II. If 5 Proper handling of James Hardie products Carrying James Hardie siding products with ColorPlus Technology flat may cause excessive bending, which can damage the finish. MOLDURAS DE ESQUINAS Figura 2 Cuando instale esquinas u otras molduras verticales, coloque las tablas en el muro y sujtelas (fig. Smoke Developed Index: 0. Install Engineered for Climate HardieWrap weather barrier in accordance with local building code requirements. Una las tablas de moldura y las lengetas planas alrededor de la apertura, tal y como se muestra en las figuras 26 y 27. The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. 4). Product: 5/4 Boards, 9-1/4 inch (235 mm) width. 4/4,5/4 boards are decorative non-load bearing trim products. Type: Textured Cedarmill, 24 inches (610 mm) by 8 feet (2438 mm). products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational, sources. 2). Type: Stucco Vertical siding panel 4 feet by 10 feet (1219 mm by 3048 mm). Minimum 1-1/2 inches (38 mm) face and straight, true, of uniform dimensions and properly aligned. Type: Bevel Channel 10-1/4 inches (260 mm) with 9 inches (229 mm) exposure. Wood Framing: 0.093 inch (2.4 mm) shank by 0.222 inch (5.6 mm) head by 2 inches (51 mm) corrosion resistant siding nails. Type: Cedarmill Vertical siding panel 4 feet by 9 feet (1219 mm by 2743 mm). Factory Finish Color for Trim, Soffit and Siding Colors: EXAMINATION IMPORT "http://www.arcat.com/gfx/csi_revision_21b.gif" * MERGEFORMAT \. Horizontal Z Flashing Trim: Aluminum extrusion to be used along horizontal control joints.
Low Profile 45 degrees Inside Corner Trim: Aluminum extrusion to be used for bay windows. Install a water-resistive barrier is required in accordance with local building code requirements. do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. Fiber-cement trim - complies with ASTM E 84 Flame Spread Index = 0, Smoke Developed Index = 5.
TABLERO DE BANDA, FRISOS, MOLDURA INCLINADA E IMPOSTA Las tablas HardieTrim tambin pueden ser utilizadas como tableros de banda, frisos, molduras inclinadas e imposta (fig. ! NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Type: Hardie Architectural Panels - Fine Sand 4 by 8 feet (1219 by 2438 mm). Alternatively corners can be pre-built (fig. Product: 4/4 NT3 Boards, 5-1/2 inch (140 mm) width. Never use high-speed power tools when cutting James Hardie products indoors.
Product: 4/4 NT3 Boards, 9-1/4 inch (235 mm) width. For proper fastener selection and fastening schedules for various wind load requirements and framing options, refer to the Technical Data Sheet at www.aspyredesign.com.
manufactured by the Hatschek process and cured by high pressure steam autoclaving.
Do not nail between lap joints. Install kickout flashing at roof-wall junctions per manufacturer's instructions. Use 16 ga. galvanized 2" long nish nails to ensure proper fastening if needed. BAND BOARDS, FRIEZE BOARDS, RAKE TRIM & FASCIA HardieTrim boards may also be used as band boards, frieze boards, rake trim or fascia (fig. Product Data: Manufacturer's data sheets on each product to be used, including: Preparation instructions and recommendations. Our product selection varies by market. Ingrese su cdigo postal en www.hardiezone.
Many other factors can influence dust exposure including jobsite ventilation, the amount of material being cut and breathing protection being used.
Allow minimum vertical clearance between the edge of siding and any other material in strict accordance with the manufacturer's installation instructions. Apply subsequent courses horizontally with a minimum 10 inch overlap at the top and a minimum 2 inch (51 mm) side lap. Specific framing and fastener requirements refer to Tables 2 and 3 in National Evaluation Service Report No. Type: Smooth vented, 24 inches (610 mm) by 8 feet (2438 mm).
8-18 by 0.323 inch (8.2 mm) head self-drilling, corrosion resistant S-12 ribbed buglehead screws. INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS PRODUCTS These instructions are to be used for HardieTrim HZ10 Boards ONLY and are NOT VALID in the following states: AK, HI, UT, ID, CO, WY, MT. Product: 5/4 NT3 Boards, 7-1/4 inch (184 mm) width. Inside Corner Trim: Aluminum extrusion to be used for inside corners. Shop Drawings: Provide detailed drawings of atypical non-standard applications of cementitious siding materials which are outside the scope of the standard details and specifications provided by the manufacturer. These products must be kept covered on a pallet off of the ground; they must never be stored in direct contact with the ground.
Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
- Church Security Protocols
- Best Shein Finds 2022
- Tru Spec Original 24-7 Tactical Pants
- Holographic Sticker Deals
- Cnc Glass Cutting Service
- Ge Wall Oven Microwave Combo 26 Inch
- Stewmac Wiring Diagrams
- Thorne Adrenal Cortex
- Jack Black Beard Oil Actor
- Custom Baby Sweatshirt Zara
- Sapphire Gold Ring Engagement
- Belt With Silver Buckle