Spring Return: 445 through 2,300 in.lbs, 3 through 150 secs power It is operated by electric current, hydraulic fluid pressure or pneumatic pressure, which the actuator then converts into motion. Torque outputs from 440 in-lbs to 2650 in-lbs, 3D dome indicator can be viewed from multiple perspectives, OVERVIEW Toll Free: 1-866-825-8672 | sales@valtorc.com. A spring return actuator is desirable in many instances where a power failure can compromise the system. Flow Measurement, Oil & Gas At ICI we focus on offering a wide array of spring return actuators for any application. Actuators can also be modified with positioners or modulating boards in order to provide modulation if it is required in the control loop. Cost-effective, Low-maintenance Spring Return Actuators Our spring return electric rotary actuators employ torsion power springs that provide a reliable mechanical actuation solution for emergency shutoff or shutdown situations. and numerous features including manual overrides, auxiliary switches, 4-20mA modulating control, several voltage options including 1-phase 24/120V/220V - 12 and 24VDC, 3-phase 220v, 380v, and 440v (view voltage chart). Optional enclosures are available to meet or exceed the NEMA 4X and NEMA 7 specifications for safe and efficient operation in corrosive, ignitable, or explosive environments. (Online Form), New! The TRIAC XC Series Actuators are CSA Certified Type 4, 4X, 6 & 7 for hazardous locations and meet UL 1203 standard. This actuator is the clear choice when a compact, efficient electric actuator is required! The actuator provides a single powered stroke, and since power is utilized for only one half of the working cycle, the actuator has lower energy use, easier installation, and less maintenance over a longer service life. An actuator is the mechanism that is used to open or close a valve. Spring return electric actuators from Indelac Controls Inc. (ICI) are specially designed for fail-safe applications using quarter-turn valves and dampers. If you do not see a particular product on this page that you need, call our sales team at 1-866-VALTORC or locally at 770-423-7100 for an immediate quote and assistance and custom application quotation. These rotary models span a torque range of 120 to 48,000 inch pounds with stroke speeds for 1/4 turn valves ranging from 0.5 seconds to 3 minutes and for multi-turn actuators from 7.5 to 30 rpm. lbs. The WE-350 model is specically designed to operate small size ball valves (1 and less), dampers and other quarter-turn devices. XEC Series 12 VDC Electric Actuators for Choke Valves, WE/XE/SE/XC Installation & Maintenance Manual Size 690 thru 25900, WED / XED - TDC Servo Card 24/120/220VAC - Quick Cal, WED / XED - TDC-400 Servo Card 12/24VDC - Quick Cal, WEM / XEM TMC4 Servo Card Detailed Maintenance Manual, WER / XER TMC4 Servo Card Modbus Module, WEM / XEM - TMC3 Servo Card Detailed Maintenance Manual, TMC3 Servo Card Thermistor Installation Manual, TMB1-RTU Modbus Control Board User Manual, WE / WEM Series Semi-Integral Local / Remote Control Module, WEP / WEQ Profibus DP Electric Actuator IOM, ABS Approved Certificate: WE/XE/SE Series, Turk Loydu Type Approval Certificate- XE/WE Series, WE-500 electric actuator wiring diagram, 115VAC/1PH, Two Position, WEM-500 Wiring Diagram, 110/220VAC 1PH with TMC-4 Control Card, WEM-500 wiring diagram, 115VAC/1PH with TMC3 Servo Card, WE-500A electric actuator wiring diagram, 24VAC/1PH, (4) Wire, Two Position, WE-500A electric actuator wiring diagram, 24VDC, (4) Wire, Two Position, WE-690 electric actuator wiring diagram, 115VAC/1PH, Two Position, WEM-690 Wiring Diagram, 110/220VAC 1PH with TMC-4 Control Card, WEM-690 wiring diagram, 115VAC/1PH with TMC3 Servo Card, WE-690A electric actuator wiring diagram, 24VDC, Two Position, WE-690A electric actuator wiring diagram, 24VAC, Two Position, WE-1350 thru WE-25900 electric actuator wiring diagram, 115VAC/1PH, Two Position, WE-1350A thru WE-2640A electric actuator wiring diagram, 24VAC, WE-1350A thru WE-2640A electric actuator wiring diagram, 24VDC, WEM-1350 thru WEM-25900 Wiring Diagram, 110/220VAC 1PH with TMC-4 Control Card, WEM-1350 thru WEM-25900 wiring diagram,115VAC/1PH with TMC3 Servo Card, WED-500 modulating electric actuator, 120VAC / 1Ph / 50-60Hz, includes OTX-100 Transmitter, WED-500C, electric actuator 24VDC, TDC-400 Servo Card with OTX-101 4-20mA Transmitter, WED-690, modulating electric actuator, TDC-100 Servo Card with OTX-100 Transmitter, WED-690C, electric actuator 24VDC, TDC-400 Servo Card with OTX-101 4-20mA Transmitter, WED/XED-1350 thru WED/XED-10500 modulating electric actuator wiring diagram, TDC-100, optional OTX-100, WED/XED-1350C thru WED/XED-2640C electric actuator 24VDC, TDC-400, optional OTX-101 4-20mA Transmitter, KE Series Electric Actuator Operation Manual, Turk Loydu Type Approval Certificate - KE Series, KE Series Electric Actuator Wiring Diagram, 110/220VAC, On/Off, KE Series Electric Actuator Wiring Diagram, 24VDC, Modulating, KE Series Electric Actuator Wiring Diagram, 24VDC, On/Off, KEM Series Electric Actuator Wiring Diagram, 110/220VAC, Modulating, KEM-1700 & KEM-3500 3D Models (Parasolid), SRXM TMC4 Servo Card Detailed Maintenance Manual, SRX-0300, SRX-1200 & SRX-1800 - 110/220 VAC 1 PH Wiring Diagram, SRXM-0300, SRXM-1200 & SRXM-1800 110/220 VAC Controlled by TMC4 (TMC-4B002), SRXM-0600 110/220 VAC Controlled by TMC4 (TMC-4B002), FSE / FSEM Series Spring Return Electric Fail-Safe IOM, BFS / BFSM Series Battery Backup Electric Fail-Safe IOM, FSE/FSEM Actuator Manual Override Installation, FSE Series Wiring Diagram - 120/220VAC-1Phase, FSEM Modulating Wiring Diagram - 120VAC / 1 Phase, BFS Series Wiring Diagram - BFS-1350 thru BFS-2640, BFS Series Modulating Wiring Diagram - BFSM-1350 thru BFSM-2640, ETI-300 / ETI-400 electric actuator wiring diagram, 115VAC/1PH, Two Position, ETI-300B / ETI-400B electric actuator wiring diagram, 12VDC, 3-Wire Control, ETI-300C / ETI-400C electric actuator wiring diagram, 24VDC, 3-Wire Control, ETI-300D / ETI-400D electric actuator wiring diagram, 24VAC, 3-Wire Control, ETI-700 to ETI-30000 electric actuator wiring diagram, 115VAC/1PH, Two Position, TMC2 (Triac Modulating Card) wiring diagram. Terms and Conditions | Distributor Login | Careers | Privacy Policy | Responsible Disclosure, A-T Controls, Inc. | 9955 International Blvd. lbs. Log in or register for a free user account now. The TMC2 can be programmed to fail in place, fail clockwise or fail counter clockwise on loss of command signal. Reversible mounting design simplifies installation and enables the actuator to spring return in either direction The actuators are ideal for use on butterfly and louver dampers with the increased benefit of self-locking EP-CYCLICAL gears, eliminating the need for unreliable solenoid brakes. The knowledge, expertise, and support you rely on. Integral 48 in. 3 through 20 secs spring, Field Selectable Options, Native Manual Override, ISO 5211 Mount, Versatile, Advanced Technology Electric Rotary Actuators Our electric rotary line offers a broad range of highly versatile actuator products. Download our 2018 product overview catalog or call us to request a copy. Click here for an overview of all the models. TheSpring Return Electric Actuatorshave spring-ending torque to 1,800 inch pounds and are also available with speed options for simple on/off or modulating applications. All the electric actuators come standard with a NEMA 4/4X aluminum housing. A scotch yoke actuator converts linear motion into rotational motion. Pharmaceutical Gate, Globe & Check Valves As with all TRIAC actuators, our E Series electrics are available with mounting kits on most ball, butterfly and plug valves. The ProMation Engineering line of quarter-turn spring return industrial actuators are robust fail-safe actuators for industry. Programming of the controller is accomplished by a combination of push buttons and seven position DIP switch without the need for a command signal. Upon restoration of power, the actuator immediately returns the valve to its normal operating position, and is ready to resume normal operation. Tel: 714 427 0877 This spring engagement mechanism design provides for extended cycle life. Click here to download (PDF), 3105 Carter Circle, Kennesaw, GA 30144 - Phone: 770-423-7100 Fax: 770-499-7483 513-731-2900, Let us know how we can help with your valve specification or application, 4665 Interstate DriveCincinnati, OH 45246, Phone: 513-731-2900Email: sales@jflowcontrols.com, Butterfly ValvesBall ValvesControl ValvesSpecialty ValvesInstrumentation Hand ValvesActuatorsAutomation Controls, About UsResourcesTerms & ConditionsTerms & Conditions of SalePrivacy Policy, 2022 JFlow Controls. Manual override is standard on non-spring return units and is achieved without the need for levers to engage the override function. The spring return fail safe functionality is for use during power failure only. Spring Return: -22 F to +149 F with heater and thermostat, Spring return SEA electric actuators fail open or closed when there is a loss of power, Spring return SEA electric actuators with clutch-less, manual override that provides manual operation if required, Additional Options and Accessories - See Data Sheet. | Cincinnati, OH 45246 | Fax 513-247-5462 | Phone 513-247-5465. Most actuators are available through the range of 12V to 230V. Actuation The battery recharges automatically when re-energized. Internal components are permanently lubricated at our manufacturing facilities, ensuring high efficiencies between moving parts, minimal routine maintenance, and quiet operation throughout the life of the actuator. SE Submersible - Type 4, 4X, & 6; IP68 (10m 72hr), Manual handwheel with torque from 690 in-lbs to 25900 in-lbs, Available motor voltages: 12VDC, 24VDC, 24VAC, 120VAC & 220VAC, Convex lens visual position indicator makes it easier to observe without water collecting on the surface of the indicator, Available motor voltages: 12VDC, 24VDC, 120VAC & 220VAC, Optional 4-20mA & 0-10 VDC proportional control.
Economy Ball Valves Widely used in applications such as petroleum, chemical, water treatment, ship, paper, power stations, heating supply, building automation, light industry, etc. Removable coupler adapts to a shorter damper shaft m) for three models mounted in tandem offer a selection that is most suitable for the application Position Indicator, On/Off/Jog/Proportional. Characterize control - Linear, Quick opening (square root) or equal percentage (square) relationship between the actuator position and the command signal. Santa Ana, CA 92704 The ISO 5211 mount pad allow for direct coupling to many valves resulting in a lower profile assembly. Food & Beverage. Call us for options if your application requires an actuator with fireproof housing (FE Series). Integral auxiliary switches provide one fixed and one adjustable switch point with line voltage capability The piston or other reciprocating part is directly coupled to a sliding yoke with a slot that engages the shaft of the component that requires rotation. Our spring return electric actuators are equipped with a hardened steel spur and helical gear drive train to guarantee reliable protection against catastrophic process failure during loss of the electricity to the system. The TRIAC FSE Series spring return electric failsafe actuator features a reliable clutching mechanism for spring failure. Click here to fill out our distributor application. The TRIAC BFS Series battery failsafe electric actuator features a sealed lead-acid (VRLA) battery with capacity for five cycles following loss of power. Pneumatic and hydraulic actuators tend to be more powerful than electric actuators. Input signals can be 4-20mA, 0-10VDC, 1-5VDC, Command signal potentiometer. 2022 10051 Porter Road, Suite 900, La Porte, TX 77571 T. 713-747-1500 F. 713-747-9928 avctexas.com info@avctexas.com . The internal modular design eliminates excess wiring and allows for simple field conversion between 2 position and proportional control. Electric Actuator Catalog (Series WE_XE_XC_KE), WE/XE/SE/XC Installation & Maintenance Manual Sizes XC-00690 thru XC-25900. WE Series (weather-proof) and XE Series (explosion-proof) electric actuators are specially designed for quarter-turn operating applications such as Ball valves, Butterfly valves, Plug valves, Dampers and similar valve automation usages. RCS actuator products from GE Energy offer exceptional automation solutions for valve and equipment manufacturers and end users in the commercial, industrial, marine and power industries. All actuators have an internal heater for moisture control, dual SPDT switches and positive mechanical stops on larger models. SEA Electric Actuators & Spring Return Electric Actuators, Approvals, Certifications & Product Documentation, Ball Valves, Unibody & 2-Piece, Iron, Steel & Alloys, CWP Rated, Butterfly Valves, Rubber-Lined, CWP Rated, Ball Valves, Unibody & 2-Piece, Brass & Bronze, CWP Rated, Gate, Globe, & Check Valves, Forged Steel, ASME Class, Gate, Globe, & Check Valves, Flanged & Wafer, Gate, Globe, & Check Valves, Iron & Steel, CWP Rated, Butterfly Valves, High Performance, Double Offset, Butterfly Valves, High Performance, Triple Offset, Ball Valves, Unibody & 2-Piece, Iron, Steel & Alloys, ASME Rated, NEMA 4X / IP67: Waterproof and dust-proof enclosure, 14 different SEA models plus four spring return models, Torque output up to 31000 lbf-in (3503 Nm), Voltage: 120 VAC. Stroke speeds for quarter-turn valves range from 1.25 seconds to 3 minutes. Spring Return Electric Actuators, Fail-Safe (SurePower), RCS Actuators Multi-Turn & Quarter Turn Electric. Trunnion Ball Valves Please note, all Valtorc quotations are valid for 60 days. Standard Spring Return motors are 50% duty rated, Working Conditions: -22 F to +149 F, 30% to 95% humidity. The actuators fail position can be either the fully open position or the fully closed position only. Accessories A pneumatic spring return actuator, on the other hand, converts energy formed by compressed air at high pressure into ether linear or rotary motion. Aerospace The shaft gives 90 rotation with a 180 option and its position is clearly shown on a raised indicator for quick visual verification. This action compresses the spring, causing a buildup of potential energy.
Sitemap 29