It is intended for use by an organization seeking to manage its environmental responsibilities in a systematic manner that contributes to the environmental pillar of sustainability. It has a better overall feel in use, the cap uses a better attachment mechanism, and we require so many at one time that it really becomes more of a single-use product for us rather than refilling the other model (which is too time-consuming and cumbersome to do). The Importance of Properly Cleaning Fiber During Termination. <>/Font<>>>/MediaBox[0 0 595 842]/Annots[96 0 R 97 0 R 98 0 R 99 0 R 100 0 R 101 0 R]>> Just thought I'd relay preference from a single customer in case there hadn't been any feedback here before. endobj This system is valid to a company engaging in development, production and supply service of fiber optical products. (invalid_anc11) I understand if not, just thought I'd provide some customer feedback on this since I don't think its likely many people go off and review fiber socket cleaners. For examples and more information about how to use these cleaners, see the Fiber Cleaning Techniquestab above. Retrieved July 30, 2018, from ISE ICT Solutions & Education: https://www.isemag.com/2016/05/fibers-dirty-secret/. Thank you for reaching out to Thorlabs. We longer have any stock of the FBC1 fiber cleaner, it was superseded by FBC250 around 2 years ago. endobj The FTDU offers a safe solution for disposal of cleaved fiber ends, epoxy and syringes, and other sharp objects. endobj Sheedy, S. (2014, August 1). %PDF-1.4 The two hole covers are connected by a plastic tab. In the field, a dry-cleaned end face placed near any uncleaned surface will attract contamination via that static charge. A second option is to use a solvent such as alcohol with Kimwipesb. The same concept can be applied to cleaning with other tools designed for fiber cleaning: wipes, swabs, and CCT tools. To remove broken fibers from connectors, we suggest our WC100 clean-out wires. Spot Cleaning Flux Residues Using BrushClean System. (invalid_anc20) Pleasanton, CA 94566

Provides a consistent and dependable cleaning every time. This website uses cookies: We use cookies to personalize content and to analyze our traffic. How Can Better Cleaning Help My Optical Power Budget? endobj distribution fiber box capacity metal ports pigtails bookmak today 37 0 obj

18 0 obj Thanks. <>/Subtype/Link/Rect[36 204.9 345.47 216.9]>> An attenuating laser safety filter in the FS201 reduces the risk of accidental viewing of active fiber emissions. We use third-party services that help us optimize our website to improve our user experience. Not because LED is using a lot of battery, but because several times it was forgotten to be switched off :) There are few suggestions which could prevent this: endobj 1) Add external led indicator, so it will be easier to spot that the scope light is not switched off It restricts the use of 10 hazardous materials in the manufacture of various types of electronic and electrical equipment: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and four different phthalates. Any help appreciated! 34 0 obj This process recognizes that dry cleaning alone achieves suboptimal results and leaves the optical connector end face charged with an electrical field that is likely to attract contamination after the cleaning process. for this part FCC-7021 - Replacement Cleaning Reel for FCC-7020, 20'. Fiber connector cleaning is an essential part of quality fiber installations. Please. cfid/cftoken/jsessionID These cookies are used to maintain a users session across our website. endstream This duster's propellant, HFO-1234ze (1,3,3,3-tetrafluoropropene), is phototransformed in the air with ~100% degradation observed by 14 days, and has a GWP of 6. How Does Contamination Cause Signal Loss Between a Mated Connector Pair? endobj Azure/Microsoft- tracking for app insights Azure's third-party cookies allow Thorlabs to track data from the user to improve the experience for our customers. Mating the fiber connectors creates a capillary action that pulls the impure solvent into the mated area (Blair, 2006). 12 0 obj <>stream <> fiber communications audio We have received your request and will reply to you as soon as possible. (invalid_anc29) 19 0 obj endobj JavaScript seems to be disabled in your browser. This is demonstrated in the image below.

The bottle has a capacity of 8 oz and is suitable for most solvents, including acetone, gasoline, propanol, MEK, toluene, turpentine, and water. 16 0 obj These cookies are necessary for the Thorlabs website to function. The best fiber optic connector cleaning method is the combination cleaning method. Both of these items are available in the CKF Fiber Connector Cleaning Kit. While it is possible to use the FBC1 for APC bulkheads, we cannot guarantee that no damage would occur as a result of using it. We will help you promote your site, backlinks for the site are here inexpensive [url=http://links-for.site]www.links-for.site[/url], Hi, Tabs on the side of the lid hold the covers open for hands-free use. xW6WpS&e]&E6}d -Q6;! This adapter features a v-groove aligned with the FC connector key on polarization-maintaining patch cables. Hello, thank you for your feedback. For the best experience on our site, be sure to turn on Javascript in your browser. Kimwipes are not ideal for cleaning optics. Using a 1.5 mm hex key or balldriver, loosen the three setscrews around the edge of the connector adapter at the end of the scope. The kit contains our TravelSAFE fiber connector cleaner (FCS3), connector cleaning sticks (MCC25), lint-free wipes (LFW90), handheld connector cleaner (FCC-7020), and a replacement reel for the handheld cleaner (FCC-7021). A resilient rubber pad beneath the cleaning surface prevents scratching, and a plastic sliding cover protects the cleaner from contamination when not in use. endobj 64 0 obj Global Warming Potential (GWP)Global Warming Potential according to the United States Environmental Protection Agency is a measure of how much energy the emissions of 1 ton of a gas will absorb over a given time, relative to the emissions of 1 ton of carbon dioxide (CO2). The LFW90 Lint-Free Wipes are ideal for cleaning fiber and connector end faces. 11 0 obj Nobody knows more about critical cleaning than the experts at MicroCare. How to Use US Conec IBC brand Duplex LC Cleaner | FS. An effective fiber optic connector cleaning process must be effective on a wide variety of contamination and provide the best possible result consistently. These dusters are chemically identical, but have different packaging and volumes; the -US version contains 10 ounces, while the -EU version contains 400 mL. Fiber Inspection Scope:The FS201 Fiber Inspection Scope, which comes with a universal adapter for FC-, ST-, SC-, and APC-terminated fibers, produces a high-quality, low-distortion image of both the connector end and the fiber. Many thanks, Look through the illuminated scope, focus on the fiber ferrule, and align the connector until the ferrule face is centered within the field of view. Using excessive solvent in optical fiber connector cleaning has its own set of pitfalls. All rights reserved. (invalid_anc14) <>/Subtype/Link/Rect[36 542.58 208.75 554.58]>> Fiber optic interconnecting devices and passive components Part 01: Fibre optic connector cleaning methods. What Can I Use to Clean My Fiber Networks? Email: sales@foscoconnect.com. Doing so repeatedly may cause the unit to fail over time. Copyright 1995-2022 eBay Inc. All Rights Reserved. Thanks for visiting FS. roitrack - This cookie is set to track which customers were referred from advertisements outside of the Thorlabs website, test cookie- This cookie is used to check if the user has allowed cookies. How Can Fiber Connectors Accumulate Static? endobj I have reached out to you directly to discuss this feedback further. My Fiber Cleaning Tools Have Static Charges. Also it would be nice to have it run on AAA batteries instead of LR44, since the first is more common (at least in our labs) and cheaper. The FS201 should not be used to inspect a fiber connected to an active light source; light sources must be disconnected or turned off prior to inspection. Eighteen pre-labeled and two blank self-adhesive labels are included. Using purpose-built wipes and swabs in conjunction with solvents engineered to clean optical surfaces adds chemical cleaning action and eliminates the problem of static generation (IEC/TR 62627-01, 2010, p. 11). 44 0 obj

<>/Subtype/Link/Rect[36 323.09 65.34 335.09]>> Operators who normally wear eyeglasses should remove them to fully inspect the fiber. This one-touch pump dispenser bottle is great for minimizing evaporation of solvents when cleaning optics with a swab or brush. Youll see exact shipping costs and arrival dates when you checkout. endobj For immediate assistance, please visit, Please select a topic for your feedback.*. <> *Please help to fill it out and submit, our service will reply to you as soon as possible. For tips on using the FCS3 and MCC25, please see the Fiber Cleaning Techniquestab above. Each vial includes eight pieces of 3" long wire along with colored sticker tabs that can be folded over the wire to improve grip.. Hi, is the FBC1 cleaner compatible with FC/APC connectors? Thanks, Industrys technical guidelines express caution when using isopropyl alcohol (IPA) for cleaning connector end faces.

<>/Font<>>>/MediaBox[0 0 595 842]/Annots[104 0 R 105 0 R 106 0 R]>> The FS201-PM adapter is like the FS201-FC adapter, except it features a V-groove that is aligned with the wide key slot on the FC/PC bulkhead. ferrule giken seikoh Live-chat with our sales team or fill out information to let us contact you. Telco, CATV, Enterprise, ITS, Contractors, Universal Fiber Optic End Face Cleaning Kits for cleaning all FTTx connections, You did not finish submitting your information to request a sample, Our website uses cookies. Hello Tom, thank you for contacting Thorlabs. <>/Font<>>>/MediaBox[0 0 595 842]>> The second issue is that IPA is a comparatively slow evaporator and therefore less likely to have evaporated completely when the connector is mated. (invalid_anc7) Unfortunately, most operators are unaware that using IPA in this application requires careful attention to avoid further contaminating the end face surface. Fiber Cleaning Using the FBC125 or FBC250 Cleaner. 3 0 obj The TravelSAFE designation indicates that the product is safe for air shipment. (invalid_anc19) We have received your suggestion and will reply to you as soon as possible. TIA Standard. Aerospace Information Report. )KJY)z{O>}x[glCyO%jmP9a=Twop{8*JStlwDSls8 <>/Subtype/Link/Rect[36 289.32 65.34 301.32]>> langabbr/language These cookies allow our website to keep track of what language a user has set. The FS201 includes the FS201-FC adapter for FC-/ST-/SC-terminated fibers (2.5 mm ferrules) and the FS201-SMA adapter for SMA905- and SMA906-terminated fibers (3 mm ferrules). Using a 1.5 mm hex key or balldriver, loosen the three setscrews around the edge of the connector adapter at the end of the scope. Additionally, mating a dirty plug cross contaminates the other plug. When it is full, securely cover both holes in the lid by inserting the tab on the cover into the slot in the lid and dispose of the canister according to the contents. (2009, September). The end result is often a halo of contamination on the end face of the connector. Bannockburn, IL, U.S.A.: IPC. The role of electrostatic charge effect on the contamination of fiber optics connectors and the ways of eliminating it. <>/Subtype/Link/Rect[36 171.13 305.44 183.13]>> Regarding the FBC1, does the product have a shelf-life? This is designed for flat polished connector types like the ones we list on the webpage. 39 0 obj Comment below your experiences using the combination cleaning method, or share your experiences using other methods, we'd love to have your feedback. The OPTIPOP R 6339, by US Conec, is a dry cloth style, cost-effective fiber optic cleaning tool for male MTP brand MPO connectors (with guide pins). Search by product or part number to get started. endobj This is a one-time use container only.

Hello, thank you for contacting Thorlabs. endobj Cleaning Jumpers and Exposed End-faces Whats the Best Way? The FBC125Cleaner cleans 1.25 mm LC or MU connectors and bulkheads with PC or APC polishes, and theFBC250 Cleaner cleans 2.5 mmSC, ST, FC, or E2000 connectors and bulkheads with PC or APC polishes. International standard IEC 61300-3-35 outlines industry-accepted inspection criteria for contamination and defects on the end face of connectors. 43 0 obj Please change this to something more like the FBC1's flexible plastic hanger around the shaft. endobj Additionally, the act of dry wiping creates a static charge that can attract contamination after the connector is cleaned (IEC/TR 62627-01, 2010, p. 11). Provides an alcohol-free solution without the use of harmful substances. Each IBC Brand Cleaner M16 provides over 525 engagements per unit. The tool uses dry cleaning for duplex connectors residing in an adapter, faceplate or bulkhead without the use of harmful substances. Smaller soils increase signal attenuation and return loss and have the potential to cause permanent damage to the connectors. endobj endobj For this task, you need FCS3 Fiber Cleaner and LFW90 Lint-Free Wipes. 46 0 obj The FS200-SMA adapter, for SMA-terminated fibers, is also included. The solvent, which needs to be purchased from a chemical distributor, can be dispensed from our BD8 one-touch pump dispenser bottle, which is great for minimizing solvent evaporation. Please, This product fully accords with the WEEE, which is an environmental regulation of the European Union and aims to enhance the improvement of collection, treatment and recycling of products at the end of their life. Instead, we recommend using the MC-5 lens tissues (sold below) to clean optics. <>/Subtype/Link/Rect[36 660.77 225.41 672.77]>> 30 0 obj How to Use Icky Pic Cleaner as a Cable Gel Solvent on Fiber Optic Cables? Fiber Optic Cleaning Kit:The CKF complete fiber optic cleaning kit bundles all of the products necessary to clean fiber. - eBay Money Back Guarantee - opens in a new window or tab, - for PayPal Credit, opens in a new window or tab, Learn more about earning points with eBay Mastercard, - eBay Return policy - opens in a new tab or window, - eBay Money Back Guarantee - opens in a new tab or window. (invalid_anc27) The combination cleaning method uses a small amount of, The combination cleaning method can be used with. Therefore, Thorlabs recommends that light sources must be disconnected from the patch cable or turned off prior to inspection. Something went wrong. This information is not shared with any other 3rd parties or services and is strictly for user experience. This tab details techniques for cleaning fibers, connectors, and fiber bulkheads using the items on this page. 51 0 obj Sticklers Fiber Optic Splice and Connector Cleaner, Cleaning Fiber Optic Networks (Part 1 of 3), Cleaning Fiber Optic Networks (Part 2 of 3), Cleaning Fiber Optic Networks (Part 3 of 3), Using Fluids Other Than Alcohol for Cleaning Fiber Optic Connectors, Comparison of Nonflammable Fiber Optic Cleaning Fluid with IPA Alcohol, Best Practices for Cleaning MIL DTL 38999 Connectors, Clean & Inspect: What IEC 61300-3-35 Means to You, Best Practices for Cleaning ODC Connectors, Recommended Best Practices for Cleaning Fiber Optic Connectors, 5G Network Reliability - How Training and Tools Help, A Sticky Situation: Removing Electrostatic Charges Improves Fiber Network Performance, An Excellent IPA Replacement for Fiber Cleaning is Here, Cleaning Challenging Military Fiber Optic Connectors, Cleaning High Density Fiber Connections in Giant Data Centers, Ultra High Fiber Count Cable - Managing Cleaning Challenges, Disaster Recovery in Fiber Optic Networks, Don't Let Dirt on Fiber End-Faces Derail Your Cell Phone Network, Best Practices for Cleaning MT and ARINC801 Connectors, The Proper Method to Clean APC Fiber Optic Connectors, The Effect of Static on Fiber Optic End-faces, The Dos and Donts of Cleaning Fiber Optic Termini, The Seven Deadly Sins of Fiber Optics Cleaning, Contamination Beware: Cleaning 101 for Fiber Optics, Cleaning OptiTap FTTH Connectors Best Practices, Controlling Static on Fiber Optic Networks eGuide, Use this click-to-clean tool onLC/UPC, LC/APC, MU/UPC, MU/APC connectors, Also works on some hardened 1.25 mm connectors, Use on outside plant and premise networks, Cleans most ferrule stub and lens-based SPF+ transceivers, both in and out of adapters, High purity cleaning strand removes dust, particulate andoil contamination, Pen-style tool cleans 90% of all connectors with just a single click instead of 2-4 clicks, Gentle activation will not damage end-faces during cleaning, Long throw, so more cleaning ribbon is used on every activation for better cleaning with every click, Long barrel length to fit inside high fiber-count panels without disrupting the adjacent connectors, Use for wet/dry cleaning of heavily soiled connectors with the, Refill cartridges perform 750+ cleanings, with a 30% savings over the cost of a new cleaner. In order to see the entire field of view, the rubber eyepiece should be as close as possible to the operator's eye. we do use E2000 connectors a LOT in our lab and notice a lack of adapters for E2000 to fiber microscopes. Please note that Kimwipesare sold in cases, with 12 boxes per case and 280 Kimwipesper box, and partial cases cannot be provided. <>stream Too much solvent will be evident if its detected under a microscope immediately after the cleaning process. All Orders Get 5% Cash Reward. The FS201-FC is not backwards compatible with the previous generation FS200 Fiber Inspection Scope.

What's the Best Way to Clean Plastic Clad Silica Fiber? These cookies are set and maintained by Microsoft. <>/Subtype/Link/Rect[36 458.16 240.06 470.16]>> This process recognizes that dry cleaning alone achieves suboptimal results and leaves the optical connector end face charged with an electrical field that is likely to attract contamination after the cleaning process. Dirty fiber connection is a major reason for equipment failure. Arlington, VA, U.S.A.: Telecommunications Industry Association Standards and Technology Department. endobj There is no answer for the moment. Additional adapters for LC connectors and PM fibers are sold separately. endobj endobj With a high-intensity illumination system and 200X magnification, this microscope is powerful enough to offer a clear image of the fiber core as well as the surrounding cladding. Stay updated about innovation, trends, and research. <>/Font<>>>/MediaBox[0 0 595 842]>> newproductlastvisit This cookie keeps a date of your last visit so that we can populate our new products page with the newest items since your previous visit. Refresh your browser window to try again. Silicon Valley's fiber optic products distributor. 36 0 obj fiber communications audio <>/Subtype/Link/Rect[36 643.89 217.39 655.89]>> Saving Money Can I Re-Use My Cleaning Wipes? <>/Subtype/Link/Rect[36 441.28 65.34 453.28]>> Schayne.

57 0 obj IPC. Copyright 2022 by Specialized Products Company. The attached MSDS, found by clicking the () icon, is given in over twenty languages. We very seldom have to pull out the wet cleaning system to clean fiber ends anymore. We Use IPA Alcohol to Clean End-faces. 42 0 obj 4 0 obj 6 0 obj NEW Healthcare Infection Prevention sub-menu, Sticklers CleanClicker 400 Fiber Optic Connector Cleaner, Sticklers CleanClicker Cassette Cleaners for Fiber Optics, Sticklers Fiber Optic Splice & Connector Cleaner Fluid. 33 0 obj Cleaning Both Ends of a Fiber Connection Do I Really Have To? Laboratory tests demonstrate the attraction of metallic powder to optical connectors electrically charged by wiping them dry on the fabric of a typical cassette-style fiber optics cleaner (Berdinskikh, Fisenko, Daniel, Bragg, & Phillips, 2003). IEC 61300-3-35. endobj 35 0 obj 14 0 obj 77 0 obj <>/Font<>>>/MediaBox[0 0 595 842]/Annots[110 0 R]>> Place a drop of solvent (enough for a dime-sized spot) on the wipe, and then lightly draw in a straight line from the solvent over the dry wipe, removing the soils and drying the end face in one motion. <>>>/MediaBox[0 0 595 842]>> The combination cleaning method can be used with wipes, swabs, and fiber cleaning tools. The first issue is that IPA is not an effective cleaner for the wide range of soils that may contaminate optical connections. Schayne. splicing splicer oZvK/i&SVyHNh/xB ?Kyeh y7d%sHf*y Every fiber optic connector should be cleaned every time it is mated, tested, or reconfigured. <>/Subtype/Link/Rect[36 407.51 65.34 419.51]>> It is a poor solvent for some of the common soils found in optical fiber installation, such as buffer gels and oils (Blair, 2006). Seller assumes all responsibility for this listing. Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-35: Examinations and measurements Visual inspection of fiber optic connectors and fiber-stub transceivers. The following is an end face that was contaminated with a sharpie marker to test cleaning. Look through the illuminated scope, focus on the fiber ferrule, and align the connector until the ferrule face is centered within the field of view. endobj The same concept can be applied to cleaning with other tools designed for fiber cleaning.

The string that holds the cap on for this product is extremely annoying while in use. (invalid_anc17) endobj FS U.S. Lens tissue will not leave lint or fibers on the optic and can be used to wrap an optic before placing it in a storage container. Cleaning Unterminated Fiber Using the CKF Fiber Connector Cleaning Kit.

endobj Please note that under normal operation, the focus adjustment knob should not be rotated to its limits. <>/Subtype/Link/Rect[36 525.7 65.34 537.7]>> Progressively adjust the three setscrews until the end face is in the center of the scope view. Connector Cleaning Sticks, 10 Cleaning Sticks per Package, 5 Packages per Box, 1.25 mm LC and MU Fiber Bulkhead and Connector Cleaner, Replacement Cartridge for FBC125, Pack of 2, 2.5 mm SC, ST, FC, and E2000 Fiber Bulkhead and Connector Cleaner, Replacement Cartridge for FBC250, Pack of 2, Universal Fiber Connector Cleaner, 20' Spool, Replacement Cleaning Reel for FCC-7020, 20', Lens Tissues, 25 Sheets per Booklet, 5 Booklets, Lens Tissues, 25 Sheets per Booklet, 50 Booklets in a Closeable Box, m. 32 0 obj <>/Subtype/Link/Rect[36 306.21 180.05 318.21]>> The FCC-7020 UniversalFiber Connector Cleaneris a great alternative to alcohol or solvent. <>/Subtype/Link/Rect[36 339.97 183.37 351.97]>> <>/Subtype/Link/Rect[36 373.74 65.34 385.74]>> Live/LivePerson/Live Person (Conversational Cloud) uses information stored in cookies to maintain session data and to identify returning visitors by saving Conversational Cloud-specific data such as visitor ID and last chat date. <>/Subtype/Link/Rect[36 356.86 318.13 368.86]>> Cleaning Unterminated Fiber:For cleaning unterminated fiber, there are two options. Can High Power Lasers Damage Fiber Networks? endobj

, US Conec IBC Brand Cleaner LC, for LC Duplex Connectors (525+ Times). 60 0 obj 2) Add switch-off timer, for example, 5 minutes. Unreliable Cleaning Methods: How to Not Clean Your Fiber Connectors. 75 0 obj First, follow the basic steps above to inspect a test fiber. Below are examples of the impact of fiber contamination: You cant assume that new connectors out of the package will be sufficiently clean. IPC-8497-1. endobj Use the "Contents" space on the label to clearly indicate what is inside. 62 0 obj Retrieved July 30, 2018, from Chemtronics' website: https://www.chemtronics.com/Content/Images/uploaded/documents/HaloEffect.pdf.

Sitemap 3