San-VijTurbine flow meters are designed for the volumetric measurements of fluids. Turbine flow sensor heart is high accurate and balanced turbine rotor and pickup coil, mehaniccal energy ( velocity) of fluid passing through the flow meter rotate a rotor, an angular velocity of rotor proportional to fluid flow rate (mechanical energy /velocity) in the flow path ,through pickup coil generate electrical frequency proportional to angular velocity of turbine rotor, and flow rate of fluid, Enclosure : S.S-304/S.S-316, Shaft : Hard Stainless Steel-316 with, Accuracy : +/- 0.5 or 1% FSD, Fluid &Ambient temperature: -20 to 120 Deg. Using EEPROM technology can store the cumulative total and the instrument system. Copyright 1996-2022 IndiaMART InterMESH Ltd. All rights reserved. flow gas turbine 20ma pulse meters meter output natural china Sensor installation: connect the amplifier to the turbine flow sensor. Pleasecontact usfor assistance. ), ( meter flow turbine bsp pulse economical pvc output inline meter water turbine pulse output removable dn80 number Under certain conditions, the rotation speed of the blade will be in direct proportion to the flow velocity. (2) 10 Display accuracy: 1 display unit. Tighten the lock nut after reaching the bottom. Turbine flowmeters produce output signals that are electronic pulses but other output signals analog(4 20mA), visual or digital- are available. overflow:hidden; 5 Our specialists are here to help you find the best product or part available for your application. turbine diesel fuel hydraulic meter liquid flow control oil type flowmeter pulse output larger (7) Specifications critical for measuring range and viscosity, 2009 - 2022 instrumentationtoolbox.com. 32 Current output type (4 -20) mA: 1 Its value can be taken: when V<100mV, d=1.0; Liquid turbine meters serve a variety of hydrocarbon applications, including fiscal and custody transfer, check metering or blending/batching.

), ( From the graph, the minimum flow that will guarantee a linearity of -0.25 or +0.25 is 100litres/min. (1) Digital signal output The output of the turbine flowmeter is a pulse digital signal proportional to the flow rate. 1/2" Turbine Flow Meter, 304SS, Pulse Output, 6.6 GPM, Temperature Connectors, Panels and Block Assemblies, Temperature and Humidity and Dew Point Meters. All Rights Reserved. ), Learning Instrumentation And Control Engineering, Industrial Motor Starters and Starting Methods, Electrical Protection of 3 phase Motors: Types and Protection Schemes, Understanding the Technical Specifications on the Nameplate of Solar Panels, A Guide to Solar Panels Power Installations, How to Specify Electric Motors for Hazardous Locations, Understanding Battery Technical Specifications, Instrumentation Books for Instrument Engineers and Technicians, Sizing Orifice Plates with Daniel Flow Calculator. We will be in touch soon. (3) Very high-pressure capability: 6,000psi. Improve your workforce with a full range of training options from Emersons Educational Services. In order to ensure that the full display instrument has sufficient sensitivity to the pulse signal output by the turbine sensor, it is necessary to increase the signal-to-noise ratio. The induced signals, after being amplified and rectified will form a continuous rectangular impulse wave with certain amplitude which may be remotely transmitted to a display instrument indicating the instant flow and the cumulative flow of fluid. ), ( (4) Signal transmission line requirements These materials help the meter to maintain accuracy and mechanical integrity when measuring the corrosive and abrasive fluids found in many industries. Output signal wiring: pulse output type amplifier has three external leads, a positive power supply (such as red wire), pulse output (Such as white wire) connect with other display instruments or equipment, and ground the shield.

The first line displays the instantaneous flow rate, and the second line displays the cumulative value. Note: Please be sure to complete all wiring and check whether the wiring is correct before turning on the power. Micro-Flow Polypropylene Sensors For Low Flow Applications. The FTB-900 Series is a low cost Liquid Turbine Flow Meter with an amplified square wave pulse output available in 12 sizes covering flow ranges between 0.176 to 880 GPM. We Provide Tools and Basic Information for Learning Process Instrumentation and Control Engineering.

Therefore, in the configuration signal transmission *Highlighted options are not compatible. 0.5% of Reading Accuracy Ball Bearing Design for Economy Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life NIST Certificate for Water Included. Current output: (4-20)mA external +24V power supply DC (two-wire system). (5) Only suitable for clean liquids and gases. Wide range of measuring with very low lower flow velocity limit. Signal transmission distance: less than 250m. Please contact us if you need assistance purchasing this product in another country. SIN-LWGY series liquid turbine flowmeter is a kind of speed instrument, which has the advantages of high accuracy, good repeatability, simple structure, small pressure loss and convenient maintenance. Stay in touch with us to get latest news and special offers. When liquid flows through the casing of the sensor, the impulse of fluid will provide the blade with a rotation moment as there is an angle between the blade of the impeller and the flow direction. Masterflex Single-Use Systems and Assemblies, AW-Lake Turbine Flowmeter 1/2" 0.9-9.0 GPM -pulse output, Turbine Flowmeter 1/2" 0.9-9.0 GPM -pulse output, You have successfully subscribed to our newsletter, Add more products on the full Quick Order page, Gear and Positive Displacement Flowmeters, Masterflex Pump Head Roller Material Compatibility, MasterSelect Pump Configurator and Selection Tool, Fluid temperature of -150 to 450F (-101 to 232C), Meters with display show flow rate, total, and real-time clock. The rimmed rotor improves pulse resolution, particularly in DN150 (6-in) and larger line size meters. Analog signal output }. (3) On-site display type

), ( ), ( 304SS Liquid Turbine Flow Meter, Pulse Output. 2 Turbine flow sensor model no wise Technical data: Model no Line size Range, BT-DTFS-004 04 mm 40~400 L/H, BT-DTFS-012 12 mm 600~6000 L/H, BT-DTFS-025 25 mm 1000~10000 L/H, BT-DTFS-040 40 mm 2000~20000 L/H, BT-DTFS-050 50 mm 4000~40000 L/H, BT-DTFS-080 80 mm 10000~100000 L/H, BT-DTFS-100 100 mm 20000~200000 L/H, BT-DTFS-150 150 mm 30000~300000 L/H, BT-DTFS-200 200 mm 80000~800000 L/H, Fuel Consumption Meter | Diesel Flow Sensor, Oval Gear Positive Displacement Flow Meter, sight glass flow indicator with Liquid flow sensor, Helical Rotor Positive Displacement Flow meter, Plastic Helical Rotor Flow Sensor and Meter, Turbine Flow Meter - Full Stainless Steel, Electromagnetic flow meter / BTU/Heat/Energy flow meter, Smart battery operated electromagnetic flow meter with inbuilt GPRS, Vortex flow meter - IBR approved Steam Flow Meter, Inteligent Flow Rate Totalizer - Mass, Volume, Steam, BTU, Hydrostatic level transmitter - vented and non vented. ), ( The effective value of the output voltage of the coil, mV; d is the coefficient, m/mV. 1% of Actual Flow Accuracy Includes 3-point NIST certificate Pressure Rating Up to 345 bar (5000 psi) Stainless Steel Construction Economical Easy Maintenance Design. Masterflex is now part of Avantor See press release >. The advantages are easy to accumulate and easy to send into the computer system. No.9-1 Haifu Road Dalian Bonded Area Pilot Free Trade Zone Liaoning China 116001, The premier global supplier and export of exceptional instruments and industry products, When it comes to Instrumentation, we are the one you need! Dedicated to the success of your entire fluid path from research to production since 1955. Options compatible with previous selections will be in bold. The angular (rotational) velocity of the turbine rotor is directly proportional to the fluid velocity flowing through the turbine.

316 SS Turbine Flow Meters w/Pulse or Current. One-stop supplier of industries meters and solution provider. Turbine flowmeters are engineered to accurately measure the flow of liquids and gases in pipes. By selecting a new country/region, product(s) may be unavailable and items in your shopping cart will be removed. }, Failed to Save Configurations, Click on Configure Button Start Again. The sensor is of hard alloy bearing thrust type, which mayguarantee the precision and improve the wear resistance performance as well. Simple and firm structure easy for installation and dismantling. Signal transmission distance: less than 250m. Powered by, ( Edit these specs to order a different model. .product-calibration-tag a{padding-left: 0px !important; background: none !important;}div#sfdcChatStart,.helpButton{display: none;}/* Reduce font on cart page for CA only */ html[lang="en-CA"] .cart-header .cart-overview, html[lang="fr-CA"] .cart-header .cart-overview{font-size: 10.5px;}@media screen and (min-width: 1024px){.product__list--wrapper h1.results.hidden-xs.hidden-sm{margin: 0 auto; width: 98.5%; padding: 0 0 10px;}}@media screen and (max-width: 1024px) and (min-width: 1366px){.product__list--wrapper h1.results.hidden-xs.hidden-sm{margin: 0 auto; width: 98.8%; padding: 0 0 10px;}}/* mini-cart dropdown on mobile */.mini-cart-modal{right: 0px;width: 368px;} @media screen and (max-width: 1024px) and (min-width: 769px){.page-articleDetailsPage .product__list--wrapper .pagination-bar.top .pagination-toolbar{width: 100%;}}@media only screen and (max-width: 640px){.page-articleDetailsPage .product__list--wrapper .pagination-bar.top .pagination-toolbar{width: inherit;}}.seo-widgets.related-products .wrapper .product.desc {font-size: 13px;line-height: 16px;letter-spacing: 0.16px;color: #696969;padding: 0px;margin-top: 12px;}.seo-widgets.related-products .wrapper .product.desc a {height: 32px;overflow: hidden;text-overflow: ellipsis;display: box;display: -webkit-box;display: -ms-box;display: -moz-box;line-clamp: 2;-webkit-line-clamp: 2;-webkit-box-orient: vertical;}/* Hide chat button on solutions page */.solutions-banner-container .chatBtn {display: none;}.incredible-expertise .incredible-expertise-left .image-container .image img{height: auto;}.one-third-two-third-container .right-section .tab-content .content-card .article-content{margin: 0 auto 0 0}a.sub-level-link.dropdown-item[href*="/resources/industry/spectris-companies"] { Phase Ii Flat No A -202 Shivtirthnagar Paud Road Kanchanban Society S No 109/1 3 Kothrud Pune - 411038, Maharashtra, India, Phase Ii Flat No A -202 Shivtirthnagar Paud Road Kanchanban Society S No 109/1 3 Kothrud. Product(s) in your cart may not be available in the selected country and will be removed from your cart if you choose the SELECT button below. Turbine flow sensor heart is high accurate and balanced turbine rotor and pickup coil, mehaniccal energy ( velocity) of fluid passing through the flow meter rotate a rotor, an angular velocity of rotor proportional to fluid flow rate (mechanical energy /velocity) in the flow path ,through pickup coil generate electrical frequency proportional to angular velocity of turbine rotor, and flow rate of fluid,Turbine flow sensor output is direct pick up coil / amplified pulse/ linear current or voltage. The output frequency of the pickoff is proportional to the flow rate. (4) Measurement of non-conductive liquids. 304 SS Turbine Flow Meters With 37 Flare. High resistance to electromagnetic interference and vibration. (2) Temperature range of fluid measurement: -450 to +6000 degree Fahrenheit. Please enable JavaScript to use this website. The repeatability of the meters ensures quality measurement over a wide range of flow rates, temperatures, compositions and viscosities. You message has been sent! Download our informative tech guide to increase your liquid turbine meter IQ. Not all combinations are valid. The turbine meters expanding blade hanger assembly holds the turbine rotor in alignment with the fluid flow. This incremental output is digital in form, and as such, can be totalized with a maximum error of one pulse regardless of the volume measured. @media screen and (max-width:1024px){ 15 Errors were found with the address you provided. 6 Proven, cost-effective technology that offers highly reliable, repeatable measurement with minimal maintenance required. (5) Capability of heating measuring device. Output signal amplitude: + 12VDC power supply amplitude is about 10V,+24VDC power supply amplitude is about 20V. A major advantage of the turbine meter is that each electrical pulse is also proportional to a small incremental volume of flow. Our Global Service Centers support all your service requirements or technical queries. Call or Email us and we will make sure you get the right product or part for the job. The transmission cable is required to be at the end of the display instrument. Compact sizeMeasurement in any meter orientationOperating pressure up to 362.50 psi (25 bar)Temperature range of 4212 F (20100 C)Accuracy of 3%Resolution up to 83,000 ppg (22,000 ppl), depending on the model. C, high electric level : High than 8 VDC( input voltage 12 VDC), low electric level : lower than 0.8 VDC( input voltage 12 VDC). https://www.indiamart.com/san-vijengineers, SS316 / SS304 WITH DELRIN ROTOR,CERAMIC BUSH BEARING. Do not reverse the connection, otherwise, the amplifier board may be easily damaged. The meters are rugged, reliable & precise instruments suitable for all Industrial Chemicals, Fuels etc. ), ( Wiring: The pulse output amplifier has three external leads, such as red wire, white wire, and a shield. Sign up to receive the latest in industry news, products, & services. Display units offer you the selection of rate, total, reset of the total, programmable sleep mode, and real-time clock done via magnet wand provided on display when cover cannot be removed (such as in an explosion proof area like an oil platform), or via buttons on display for non-explosion proof models. Limit the maximum length of the signal line. The turbine meters also minimize fiscal measurement uncertainty by delivering high-frequency pulse resolution to account for minute increments of the flow rate. } These turbine flowmeters are designed with only one moving part for easy cleaning. 2022 Emerson Electric Co. All rights reserved. Flow impinging upon the blade causes the rotor to spin at an angular velocity that is proportional to the flow rate. Offer meter-mounted display, pulse, or 4 to 20 mA output versions. 7

The meter features a 304 stainless steel housing and rotor support, CD4MCU stainless steel rotor, and abrasion-resistant tungsten carbide rotor shaft and 316SS bearings. Quickly access contact information for your area representative. How a Current to Pressure Transducer Works, Common Symbols Used in Process and Instrumentation Diagrams, How to Measure Electric Motor Insulation Resistance, How to Test 3-phase AC Motor Windings with an Ohmeter, How to Read Torque Speed Characteristics of AC Motors, Instrument Abbreviations Used in Instrumentation Diagrams, How to Convert Thermocouple Milivolts to Temperature, Principles & Formulas for Flow Measurement. 22 The signal transmission line should be shielded cable to prevent inductive noise from outside. When powering the line, you must pay attention to the following points:

The blade will rotate as the friction moment and the fluid resistance are overcome, and it will reach a stable speed when the moments are at balance.

They measure flow on a volumetric basis. Please verify your address.

It is used to measure the volume flow of low viscosity liquid in closed pipe. Turbine flowmeters are applicable to clean fluids over a pressure range from sub-atmospheric to over 6,000psi and temperatures from -450 to about 6000 degree Fahrenheit. Turbine meters are simple to operate and maintain, and in service worldwide as a reliable, cost-effective method for achieving accurate flow measurement. A liquid turbine meter is used for volumetric total flow and/or flow rate measurement and has a relatively simple theory of operation. Output signal: (4-20)mA or (1~5)V, 4mA corresponds to zero flow of turbine flow sensor, 20mA corresponds Emerson is where technology and engineering come together to create solutions for the benefit of our customers, driven without compromise for a world in action. As fluid flows through the meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. ), ( bvseo-msg: The resource to the URL or file is currently unavailable.. Wiring: (4-20) mA output type amplifier external leads (such as red wire and white wire). (3) At least 15 diameters upstream and 5 diameters downstream of straight pipe is. ), ( Small signal removal function. After the turbine flow sensor is installed, put the amplifier Screw it to the turbine flow sensor, and tighten the lock nut after the amplifier reaches the end. The shield is grounded. Turbine flow meters are designed to maximize throughout and minimize pressure drop, maintain high flow rates over an extended flow range and offer pulse output that is linear to the flow rate. This design ensures linearity and repeatability, making the turbine meter an ideal device for fiscal flow measurement. Process Control for Power & Water Industries, SCADA, Remote Terminal Units (RTU) & Flow Computers, Programmable Automation Control Systems (PLC/PAC), AVENTICS Product Calculation Pneumatics, Integrated Solutions for Air Conditioning, Commercial Space Heating Scroll Compressors, Residential Space Heating Scroll Compressors, Click to view our Accessibility Policy and contact us with accessibility-related issues, Residential Construction & Home Improvement. .top-level { The meters are often installed for measurement during crude oil production, tank farm/storage inventory control, floating production, storage and off-loading (FPSO) as well as refined product loading and offloading. The rotation of turbine rotor generates electrical pulses in the pick off attached to flow meter housing.

Sitemap 3