Allow unit up to 15 minutes to complete start up period . WARNINGTo avoid electric shock, do not plug the concentrator into an AC outlet if the concentrator cabinet is broken. Smoking during oxygen therapy is dangerous and is likely to result in facial burns or death. Supplemental oxygen is not addictive. Indications For UseThe DeVilbiss Oxygen Concentrator is intended for use as an oxygen concentrator to provide supplemental low flow oxygen therapy in the home, nursing homes, patient care facilities, etc. DeVilbiss warrants this equipment to be free from defects in workmanship and materials for three (3) years from date of factory shipment to the original purchaser, (typically the healthcare provider) unless contractually specified otherwise. Check filter door vents and ensure that the openings are not blocked. 2 0 obj This device contains electrical and/or electronic components that must be recycled per EU Directive 2012/19/EU-Waste Electrical and Electronic Equipment (WEEE). 2 . All lights are off when the power switch is On . Audible alert is pulsing . Use only water-based lotions or salves that are oxygen-compatible before and during oxygen therapy. The port is only for use with FDA-cleared filling devices with compatible oxygen input specifications. Keep body parts a minimum of 32 (81.2 cm) away from this area. The new filter door is compatible with older models, and the old filter door will still be compatible with the new 525/1025 models. Your delivery settings of the oxygen concentrator should be periodically reassessed for the effectiveness of therapy. In most cases, they are already attached to the oxygen tubing. You may need a rebuild compressor or a fresh set of sieve beds! Thread the wing nut located on the top of the humidifier bottle to the oxygen outlet so that it is suspended (Figure 2). Press the concentrator circuit breaker reset button located below the power switch . 1. Do not attempt any other maintenance.
Upon verification of the warranty status, instructions will be issued. Follow disinfectant manufacturers instructions. 3 . Installation of 515LF-607 low output flow meter package will cause the low flow alarm to not work and will prevent the device from meeting the requirements of ISO-80601-2-69:2014 Section 201.13.2.101. Oxygen Tubing Connection With Humidification:If your physician has prescribed an oxygen humidifier as part of your therapy, follow these steps (If using a prefill, go to step b. If used with the oxygen accessories, the fire stop device should be located as close to the patient as practicable. Do not attempt to defeat this safety feature.NOTE To check your oxygen concentrator and accessories for proper operation; 1. Never use petroleum or oil-based lotions or salves to avoid the risk of fire and burns. The surface temperature of the exhaust vents on the bottom of the unit may exceed 105.8F (41C) under certain conditions. Proper cleaning is discussed in the Caring For Your Concentrator section on page 8. Intended UseThe DeVilbiss 5 Liter Oxygen Concentrator intended use is to provide supplemental low flow oxygen therapy for patients suffering from COPD, cardiovascular disease, and lung disorders. OxygenPlus Medical 2019 Powered by Shopify, Devilbiss Oxygen Concentrator Replacement Parts. If your unit loses electrical power or fails to operate correctly, the Patient Alert System will sound to signal you to switch to your reserve oxygen system (if provided) and contact your DeVilbiss provider. concentration is not within specification, the provider should refer to the service manual section on Troubleshooting. Check the output flow by placing the end of the nasal cannula under the surface of a half-full cup of water and look for the bubbles. Today, many people suffer from heart, lung and other respiratory diseases. If unable to leave the room, you must wait 10 minutes after you have turned off the oxygen concentrator before smoking. When the unit is turned On, all three lights (Service Required, Low Oxygen, and Normal Oxygen) on the front panel will illuminate briefly and an audible signal will briefly alarm confirming that the LEDs and audible signal are functioning properly. Copyright Bar O2 Limited T/A the OxygenStore 2001-2021 ~ All rights reserved ~Company Registered in UK No 04192727, VAT Registration No 770 4717 24 ~EORI GB770471724000 ~ Dun and Bradstreet D-U-N-s No 232439047, Compressor filter for Devilbiss 525 concentrators LL201, Devilbiss Foam Cabinet Air Filter 303DZ-605 (F605) - 6 Pack, Devilbiss 6 X Air Filter 444-514, Compact 505 and 515 Concentrators, Final Bacteria Filter Devilbiss PV5LD-651 (BF600), Devilbiss 505DZ-607 Standard 1-5 L Flow Meter, Devilbiss HEPA Filter 303DZ-639- CF105 For Compact 505 and 515 Concentrators, Devilbiss Power Switch 4 Terminal 505DZ-508, Devilbiss Intfoam cabinet filter 303dz-605 - F605, Devilbiss PL T Accumalator Fitting 444-582, Drive Devilbiss 1025 Pressure Relief Valve for 025 1025D-614, Drive Devilbiss 1025 Compressor Rebuild Kit 1025K-643, Drive Devilbiss 1025 Sieve Beds (Pair) 1025D-619, Drive Devilbiss 1025 Pressure Regulator Assy 1025D-612, Drive Devilbiss 1025 Power Switch 1025D-508, Drive Devilbiss 1025 Auxiliary Oxygen Port 525DD-635, Drive Devilbiss 1025 O2 Outlet Port (Long and Grey) 525D-170, Drive Devilbiss 1025 Motor Mount PKG 4/PKG 1025D-609, Drive Devilbiss 1025 Heat Exchanger Tube 1025D-655, Drive Devilbiss 1025 1/8" ID (Blue) 444-554, Ex Demo, Reconditioned and Used Home Oxygen Concentrators, Masks, Cannula, Headsets, Venturi Valves Tubing & Connectors, Capnography, Pulse Oximeters & Oxygen Meters, Oxygen Cylinder Carrying Cases & Medical Bags.
Non-infectious used accessories (e.g. PROVIDERS NOTES Cleaning and Disinfection When There is a Patient ChangeDeVilbiss Healthcare recommends that at least the following procedures be carried out by the manufacturer or a qualified third party between uses by different patients.NOTE If the following described complete processing of the concentrator by an appropriately trained individual is not possible, the device should not be used by another patient.NOTE If preventive maintenance is due at this time, these procedures should be carried out in addition to the servicing procedures. Find all the DeVilbiss 5 Liter Oxygen Concentrator parts you need, including all Respiratory > Oxygen > Concentrators type models for Drive Medical products. Do not use the unit if the power cord is damaged. Check the flow meter to make sure that the flow meter ball is centered on the line next to the prescribed number of your flow rate. After 25 plus years in the business, OxygenPlus has hand picked the best vendors that offer the best quality parts available. Vitality Medical. ): NOTE Your physician has prescribed either a nasal cannula or a face mask. Mild dish soap (2 tbsp) and warm water (2 cups). WARNINGWhen using the Transfer Caddy with a Transfill device, always keep the system on a flat surface. Fill the humidifier bottle as per the manufacturers instructions. Pay special attention to all safety information Imminently and potentially hazardous information is highlighted by these terms: This instruction guide will acquaint you with your DeVilbiss oxygen concentrator.
As a precaution, your DeVilbiss provider may supply you with a reserve oxygen system. 5. Oxygen causes rapid burning. Do not leave the nasal cannula or mask on bed coverings or chair cushions if the oxygen concentrator is turned on but not in use. 1 . After the recommended exposure time, all surfaces of the concentrator should be wiped with a clean lint-free cloth dampened with drinking quality water no warmer than room temperature. Keep the oxygen concentrator and cannula at least 2 m (6.5 feet) from hot, sparking objects or naked sources of flame. DeVilbiss Customer Service Contact InformationCustomer Service (USA): 800-338-1988International Department: 814-443-4881 /[emailprotected]Ordering Non-Warranty Replacement PartsOrder non-warranty parts and literature from your DeVilbiss provider. Make sure that you read and understand this guide before operating your unit. Unapproved filters are used with the unit. If proper flow is obtained, clean or replace humidifier. 2. We have parts for legacy machines like the Puritan Bennett 492 or Healthdyne BX-3000 up to the Healthdyne Alliance and Devilbiss MC Series, all the way up to the latest machines like the Respironics EverFlo or Invacare Perfecto and Airsep VisionAire. Attach the oxygen tubing directly to the humidifier bottle outlet fitting (Figure 3). Read this entire guide before using your DeVilbiss concentrator. If the above remedies do not work, contact your DeVilbiss provider . If the indicator ball does not drop to zero, check all connections for possible leaks. %PDF-1.6
Do you turn on the power switch, and nothing happens? Your DeVilbiss concentrator is now ready for use, properly position the cannula with the nasal prongs facing upward, insert the prongsinto nose. To avoid electric shock, do not plug the concentrator into an AC outlet if the concentrator cabinet is broken. We can now offer you new OEM parts, new quality aftermarket parts, as well as quality OxygenPlus reconditioned components that you can trust. Certain humidifiers and accessories may impair the devices performance. RETURN AND DISPOSALThis device may not be disposed of with household waste. :f\D%+l2\aM|j-3%8D\( bF"\j(Ho|AaWHx Q(J.G8$O 22HJD{|
w1X3 /]T,K?JIgzI]N/PG\ ,>T=q$(Vr]P%jxqU T %B,E9!&_z !XUC ?'#rr>-$RGE Wrap the cannula tubing over the ears and position in front of body (Figure 4). Oxygen makes it easier for a fire to start and spread. Check your home circuit breaker and reset if necessary . 1 . Pay special attention to all safety information. Audible low-frequency vibration sound is detected . Over 2,500,000 satisfied customers since 2000, 7 FDA Approved Air Purifiers for Covid-19. Our company is operated by industry professionals with more than 35 years of direct experience in providing customers with all types of specialty wheelchairs. A mask or any nasal cannula can be used with continuous flow delivery and may be sized according to your prescription as recommended by your homecare provider who should also give you advice on the proper usage, maintenance and cleaning. WARNINGDo NOT use lubricants, oils or grease. Does your "Low Oxygen" light taunt you? Call us at 800-236-4215 for assistance in locating your Spark parts.
Check power cord connection at the wall outlet . The device and accessories have not been evaluated for safety in an MR environment. Also, do not forget that we have a full line of replacement filters for every make and model of Oxygen Concentrator and also CPAP and BIPAP machines! Some electromagnetic sources may not be apparent, if you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, disconnect the power cord and discontinue use. Use a different wall outlet if the situation occurs again . Disassemble the system prior to moving. be used with the specific combination of parts and accessories that are in line with the specification of the concentrator manufacturer and that were used while your settings were determined. Product ID #'s 303DZ-639, 505DZ-604, 306DS-611, 306DS-616, 303DZ-605, MC44D-605, 525D-622, PV5LD-651 and the 525DD-639. nasal cannula) can be disposed of as residential waste. This warranty shall be voided, and DeVilbiss shall be relieved of any obligation or liability if: THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES AREEXCLUDED THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES AREEXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. And many or our smaller parts also qualify for free ground shipping to continental US states. These Oxygen Concentrator Filters are replacement filters for DeVilbiss Oxygen Concentrators--DeVilbiss iGo Portable Oxygen Concentrator and the DeVilbiss 5 Liter 525DS and its 10 L 1025DS 10L Oxygen Concentrator. NOTE The OSD performance at 41F (5C) to 95F (35C), 93% R.H. through voltage range on the 525DS verified at 670m.The maximum recommended flow is 3 LPM when an oxygen bottle is being filled with oxygen from the auxiliary oxygen port.Use of the 515LF-607 low output flow meter package or other low output flow meter accessory will prevent the device from meeting the requirements of ISO-80601-2-69:2014 Section 201.13.2.101.Specifications are subject to change without notice. Detach the humidifier from the oxygen outlet. VitalityMedical.com is for informational purposes only and should not be used as medical advice, to diagnose, or treat patients. <>stream Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the oxygen concentrator, including cables specified by the manufacturer. (The maximum flow meter setting is 3 LPM when an oxygen bottle is being filled with oxygen from the auxiliary port.). If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. 1 . Please enable JavaScript. Before attempting any cleaning procedures, turn the unit Off.. If bactericidal cleaning is required, a non-alcohol-based product should be used to avoid inadvertent damage. All of our reconditioned parts and services are repaired by factory trained technicians. The device has been misused, abused, tampered with, or used improperly during this period, Malfunction results from inadequate cleaning or failure to follow the instructions, The equipment is operated or maintained outside the parameters indicated in the DeVilbiss operating and service instructions. Remove the power cord completely from the line cord strap. Do not remove the concentrator cabinet. Get the lowest prices possible on DeVilbiss 5 Liter Oxygen Concentrator parts. Auxiliary Oxygen Port (Serial numbers starting with R, N, or B): Your concentrator is equipped with an auxiliary oxygen port that can be used to fill oxygen cylinders with an FDA-cleared cylinder filling device that is designed to use oxygen from a concentrator to fill a cylinder. Contact your DeVilbiss equipment provider should you have any questions. G . The start-up may take up to 15 minutes. Some electromagnetic sources may not be apparent, if you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, disconnect the power cord and discontinue use. The unit is double insulated to guard against electric shock. Disassemble the system prior to moving.
Audible alert may be sounding . If bactericidal cleaning is required, a non-alcohol based product should be used to avoid inadvertent damage. Geriatric, pediatric or any other patient unable to communicate discomfort can require additional monitoring and/or a distributed alarm system to convey the information about the discomfort and/or the medical urgency to the responsible caregiver to avoid harm. 3 . If the oxygen. WARNINGUse of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. Before operating your unit, always check to be sure the filter door vents (located on the back of your unit) are clean. The total volume (amount) of solution required is determined by the number of concentrators in need of disinfection NOTE An alternate suitable disinfecting agent (e.g. Heavy soil should be removed with a clean lint-free cloth dampened with water. The device and accessories have not been evaluated for safety in an MR environment. If any other problems occur with your oxygen concentrator. For your safety, the oxygen concentrator must be used according to the prescription determined by your physician. Failure to do so may cause an electrical safety hazard. Press the power switch to the On position. Red Service Required light is illuminated .
3. For the best experience on our site, be sure to turn on Javascript in your browser. Warranty Claims SubmissionsThe original purchaser must submit any warranty claim to Drive DeVilbiss or to an Authorized Service Center. Comment document.getElementById("comment").setAttribute("id","a452959398799cea8435158a4a181e93");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Many of these people can benefit from supplemental oxygen therapy. On 230 volt units, also check the mains connection on the back of the unit . Contact your provider or service supplier immediately if you encounter any problems. B . Unit does not operate . If not, follow the manufacturers instructions for attachment.NOTE Your healthcare provider should verify the compatibility of the oxygen concentrator and all of the parts used to connect to the patient before use. Do not increase or decrease the flow of oxygen consult your physician. Do not remove the concentrator cabinet. Locate oxygen tubing and power supply cords to prevent tripping hazards and reduce the possibility of entanglement or strangulation. HWnkG_ Filter Replacements for DeVilbiss Oxygen Concentrators, Filter, Final Bacteria - 525DS and 1025DS, Skip to the beginning of the images gallery. How Your DeVilbiss Oxygen Concentrator WorksOxygen concentrators are the most reliable, efficient and convenient source of supplemental oxygen available today. Otherwise, degradation of the performance of this equipment could result. If you intend to smoke, you must always turn the oxygen concentrator off, remove the cannula and leave the room where either the cannula or mask or the oxygen concentrator is located. The oxygen will make the materials flammable. Failure to do so may cause an electrical safety hazard. 1 . Keep the oxygen concentrator and cannula at least 2 m (6.5 feet) from hot, sparking objects or naked sources of flame. o r D e r i n g i n F o r M a T i o n a n D P a r T S l i S T, Positive airway pressure device (92 pages), Positive airway pressure device (100 pages), Manual will be automatically added to "My Manuals", Health Care Products DeVilbiss 525KS Instruction Manual, Medical Equipment DeVilbiss 525 Series Instruction Manual, Medical Equipment DeVilbiss 535D DeVilbiss iFill Instruction Manual, Medical Equipment DeVilbiss 515A Series Instruction Manual, Medical Equipment DeVilbiss IntelliPAP2 DV63 Standard Plus CPAP Series Instruction Manual, Medical Equipment DeVilbiss Drive 1025DS Service Manual, Medical Equipment DeVilbiss 9000 series Instruction Manual, Medical Equipment DeVilbiss DV55 Bilevel Series User Manual, Medical Equipment DeVilbiss DV54 SLEEPCUBE AUTOPLUS Instruction Manual, Medical Equipment DeVilbiss iGo Equipment Manual, Drive 1025DS Figures, Diagrams And Parts List, 525 Series Important Parts Of Your Concentrator, 525KS-LT Important Parts Of Your Concentrator, Vacu-Aide QSU 7314 Series Important Parts Of Your 7314 Series Devilbiss Suction Unit, IntelliPAP DV54 Ordering And R Eturning Parts, SleepCube nCPAP Ordering Non-Warranty Replacement Parts, 1025 Series Important Parts Of Your Concentrator, 7305 Series Important Parts Of Your 7305 Series Devilbiss Suction Unit, IntelliPAP2 DV63 Standard Plus CPAP Series Replacement Items/Spare Parts, DeVilbiss IntelliPAP2 DV63 Standard Plus CPAP Series. NOTE A maximum of 50 feet (15 meters) of crush-proof oxygen tubing, plus 7 feet (2.1 meters) of a cannula, plus a bubble humidifier is allowed between the concentrator and the patientNOTE Your healthcare provider should verify the compatibility of the oxygen concentrator and all of the parts used to connect to the patient before use. Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. If the above remedies do not work, contact your DeVilbiss provider. Use of this device at an altitude above 13,123 feet (4000 meters) or above a temperature of 95F (35C) or greater than 93% relative humidity may affect the flow rate and the percentage of oxygen and consequently the quality of the therapy. DeVilbiss OSD OperationThe OSD (Oxygen Sensing Device) is a device within your concentrator that monitors the oxygen produced by your unit. Blocked or defective cannula, face mask, or oxygen tubing . Refer to specifications for details regarding parameters tested. The OSD lights on the top panel are defined as follows: If the oxygen purity falls below the acceptable level: The green Normal Oxygen light will shut off, the yellow Low Oxygen light will illuminate, and an intermittent audible signal will sound.Refer to the Minor Troubleshooting section in this guide on page 9, and switch to your reserve oxygen system. NOTE There is no portion of the gas pathways through the concentrator that could be contaminated with body fluids under normal conditions.The device patient connection may unintentionally become contaminated with expired gases for a single fault condition i.e., a hose internal to the device becomes disconnected. Use disinfectants safely Always read the label and product information before use, Always wear personal protective equipment when performing this procedure Use suitable gloves and safety glasses Cover exposed skin on arms to prevent accidental contact with a bleach solution that has been applied to the concentrator. DANGEROxygen causes rapid burning. This ratio produces a one (1) part bleach to five (5) total parts solution (1:5). The oxygen delivery setting has to be determined for each patient individually with the configuration of the equipment to be used, including accessories. The oxygen concentrator is used in home-type environments, homes, nursing homes, patient care facilities, etc. Do not use the device or accessories in an environment with electromagnetic equipment such as CT scanners, Diathermy, RFID and electromagnetic security systems (metal detectors) as it may cause unacceptable risk to the patient or damage to the oxygen concentrator. Apply the bleach solution in an even manner to the cabinet and power cord using a clean lint-free cloth The cloth should be dampened only and not dripping of solution Do not use a spray bottle to apply the solution Do not saturate the device with the solution Take care that no solution enters the vent areas on the concentrator base or the Auxiliary O2 fitting area on the back of the unit.