A pool heater is composed of switches, components and other devices that turn the heater on and off, and keep the water at the desired temperature. Use these to troubleshoot your Raypak pool heater: As mentioned earlier, using a solar cover helps you pool hold on to heat more effectively. If the burners fire, then you have a bad thermostat and it needs to be replaced. Walk over to your pool heaters breaker and reset it. Multimeter capable of checking AC volts, DC volts, and Ohms, If the unit doesnt run, check the water flow lamp, Run the pump for at least 8 hours to test heat loss, Check air flow to troubleshoot a lack of heat, Reset the breaker to troubleshoot an unresponsive display board, Look out for Raypak heat pump error codes, -Larry Pietrantonio | Satellite Beach, FL, -Chris Rogers | Falmouth, ME/Kissimme, FL, 7 Ways Heat Pump Swimming Pool Heaters Simplify Pool Heating, Balance Your Swimming Pool Water In 7 Steps, A Guide To Basic Pool Heat Pump Troubleshooting, Pool Heat Pumps & Solar Pool Heating: The Perfect Match, Pool Heat Pump Repair | Pool Heater Repair, Energy Saving Tips For Your Swimming Pool. Circuits in heaters are not difficult to troubleshoot once you understand that the components are wired in series, like a string of Christmas lights. That said since your evaporator coil sits behind a layer of metal vents, the blockage could also be there. -Is the control panel Power lamp ON? Most heaters need a minimum of 40 gpm passing through before they will fire. Although poor heating ability can be a sign of a dirty evaporator coil (more on this later), there are a few things to consider when heat loss is an issue. The evaporator coil is the part responsiblefor turning harvested warm air into usable heat for your pool. The first step along this diagnostic line involves sidestepping the gas valve by clipping a jump wire across the valves terminals (see Figure 1). If not, check out electrical connection points for damage or corrosion. Intermittent ignition devices differ from millivolt devices chiefly in the fact that IIDs require an external electrical source to power their functions. With the thermostat set high enough to call for heat, you should have a spark at the pilot-burner electrode if all the controls are good. Restrictions such as shrubbery, tall grass, dirty. Check the transformer. Check the gas valve. If there is no arc across the space, the ignition control should be replaced. If you liked this post, you might also like: Get access to exclusive swimming pool tips, special offers, and members-only news, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida, How Well Do Solar Pool Heaters Work? Instead, what youre dealing with is likely an electrical issue. Heres a four-step procedure: 1. Whether installed on the heater exterior or in its internal circuitry, the lights provide instant diagnostic information about the status of important system functions, including water flow, pressure, thermostat and gas-valve operation. This is also evidence of heat removal from the air. If your heat pump does not operate, or simply does not heat your pool water, the indicator lamps on the front control panel (see Section IV) can provide valuable clues as to what is wrong, and may even indicate precisely what the problem is. NOTE: The heat pump will not run when the Remote position is selected on the Pool/Spa selector switch and there is no remote control system attached.ir and transferring it to the pool. Sometimes when a heater is shut down for winter, the gas to the heater will be turned off at the gas valve. Raise the thermostat setting. To do this, reset the time clock dial for the longer running time, or manually operate the pump with the timer override switch. Check all electrical connections. When an IID heater wont fire, the ignition control is another suspect. Usually, the pilot generators output should be anywhere from 250mv to more than 500mv with the circuit open that is, when the heater is not running. When you know whats causing a problem with your pool heater, then fixing it is way simpler. 2012 - You want to be sure these connections are tight. To jump the gas valve, first turn off the main gas valve so the burner doesnt come on. These millivolt systems have no outside electrical hookups. To do so, remove the wire running between the gas valve and the thermostat.
Gardeners or others may have turned the unit off. After the unit has been running and then shut OFF for any reason, there is a delay before operation can begin again. Verify that the breaker is set and operating properly before calling for service. Always observe these lamps before calling a service representative. Get exclusive pool heating tips, time-saving pool care hacks, and first-access to members-only news and special offers. Often the culprit is not in the heater itself. At this point, heater manufacturers recommend that you bring in a specialist to troubleshoot the system because of the seriousness of the problem. If this lamp is OFF, but you can feel normal flow at the pool returns, check the water valves or settings.




While pool heat pumps are built to provide countless hours of heat, theystill need maintenance to stay at peak performance. Fortunately, this doesnt always mean that your pool heater is toast. If the water stops dripping, the heat pump is not leaking. Each day, a bunch of air passes through the coil. If it is low, you may have a voltage problem or faulty transformer. But dont panic over the fact that its more complicated to work on than a pool filter or pump. -Is the Heat Demand lamp ON? The No. But when you cant figure out the problem yourself, you can get pool heater troubleshooting help over the phone. If the heater doesnt shut off, you have a faulty valve that must be replaced. Figure 1: Sidestep the gas valve by clipping a jump wire across the valves terminals. Check the on/off switch. Heat pumps can produce a large amount of condensation (water) during operation. Remember that the heat pump only operates while the pool pump is running. This lamp will turn OFF if not enough water is flowing through the unit. NOTE: If the pool pump and heat pump shut OFF before the water temperature is raised to the desired level, you must lengthen the running time of both. Note: After troubleshooting any component, always remember to remove the jump wire!

-Is the pool blanket/cover being used? Check for a spark. Nothing.
A Dozen Ways to Strengthen Your Remodeling Brand, Decoding the Framing Square for Rafter Layout, New Tool: Metabo HPT MultiVolt Cordless Compressor, A Deck Builder's Guide to 'Google My Business', JLC Rolls Out Deck and Railing Skills Workbook, Webinar: What You Need to Know About Decking. West: 213-291-9276Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 954-866-1644. 24Manometer (for fan assisted units, more than one manometer will be needed). Again, a preliminary wiring check will help you avoid unnecessary effort in troubleshooting these components. Your Raypak pool heater keeps your pool comfortable throughout the seasons. Use a pocket mirror to see if the pilot is burning; never put your face or eyes where you could possibly get burned. Set your voltmeter for the proper voltage that is, above 24 volts. First, verify that its receiving 20- to 30 volts. If theres no spark, some manufacturers recommend that you pull the wire off the ignition control and hold it approximately 1/8-inch away from the ground terminal.
If the pressure gauge reads normal, proceed. Here are a few common Raypak troubleshooting codes and what they mean. By reporting on the telephone which lamps are ON and OFF, the service rep may be able to solve the problem without the expense of a service call. (This does not happen in newer models.). When you make contact with both terminals, you should get a reading of 20-30 volts. If youve gone through all the previous steps for troubleshooting heat loss, the cause of the problem might be a dirty evaporator coil. When the air is cool with low humidity, condensation may not be evident. Having the right tools from the start helps you troubleshoot your pool heater faster. Then the suspect parts are the pressure switch, high-limit switch, thermostat, gas valve and pilot generator. But if the issue is your pool heater, then youll still experience significant heat loss with or without the cover. A few areas to clean & check for blockage include: Maybe your pump turns on just fine but doesnt heat the way it used to. During initial pool heating in cold weather, it may require a week to elevate the water temperature to a comfortable level. Once you find out which part is keeping the heater off, it can be repaired or replaced. Troubleshooting heaters has been simplified with diagnostic lights, which some manufacturers include in their latest designs. Troubleshooting an IID control system calls for an AC voltmeter with a 220-volt range or greater. So what do you do when the heater wont heat? Check the unit for obstructions, such as a clogged filter pump strainer, a dirty filter, or valves not positioned correctly. Depending on the unit, the thermostat may need to be removed from a mounting to access its terminals. If everything looks normal, but your heat pump is unresponsive, contact a pool heat pump technician for advanced troubleshooting steps. Reset the breaker by switching it OFF, then back ON. By applying a solar cover, you can figure out whether its your pool or pool heater thats creating the heat loss. Any debris caught in the vents can impact air floor. There are two basic types: millivolt systems and IID systems. Combustion Analyzer needed for all commercial units. It may take some sleuthing to discover the cause of a heater malfunction. b. If you suspect that the heat pump is leaking: a. If not, the circuit breaker may be shut OFF or tripped. -Are the thermostat setting and the Pool/Spa setting correct? Figure 2: Pressure switch test in an IID system. Although all pool heat pumps need maintenance to maintain performance, a bit of troubleshooting can save you a lot of time. The last of the checks, make sure gas can go into the heater. As with the millivolt system, once external checks have been made, you can be fairly certain the heaters failure to fire stems from a faulty component in the control circuit. If you see any leaves or twigs lodged in the vents, remove them. If, however, the main burner doesnt light, you have either a problem with the pilot generator, a wiring problem in connections for the pilot generator or a bad gas valve. 2022 Poolheatpumps.com. If you replace the high-limit switch and still have a problem, check for proper water flow through the heat exchanger. Finding the bad bulb is a matter of progressing through the system and testing suspect parts in sequence until you locate the problem.
Next, jump across the pressure-switch terminals, thus electrically bypassing the pressure switch. A heater that just wont shut off can be particularly alarming. -Is airflow through the unit being obstructed? If the heater does shut off, the gas valve is OK, but you know you have a control problem. To get to the root of such problems, you should: Check the gas valve. Over time, the coil begins builds up a layer of debris, dirt, and grease from processing so much air. In any case, the procedure is the same: Jump from one terminal on the thermostat to the other.
In all cases covered in this article, theres a logical progression of checks and tests that will lead to a proper diagnosis and cue you to quick action to bring the heater back up to speed. Set the time clock to permit 24 hour per day operation. If the pilot lights and all external functions and factors have checked out, the millivolt systems inability to fire is likely to be caused by a malfunctioning component along the electrical path in the heater. This is sometimes the cause of what many describe as a pool heat pump turning off and on.
Shut the heat pump OFF and leave the filter pump running to see if the water stops dripping. Faulty high-pressure switch (shuts down to protect unit). -Is the Water Flow lamp ON? Check the temperature control.
Try moving the knob back and forth several times to clean the contacts. If you do have a spark, but the pilot doesnt light, a good bet is that you have a plugged pilot assembly or a bad gas valve.

Here, the pilot is sparked electrically only when it is needed to fire the burners. Effective Raypak pool heater troubleshooting is all about knowing what to look for, and what the signs mean. Rio Bravo, Inc. Before calling for heat pump service, gather these tools: If one day you wake up and your pool heat pump stops running, the first thing to check is your water flow.
- Date Outfits For Teenage Girl
- White Puff Sleeve Top Short Sleeve
- Steve Madden Platform Slides
- Neil Simon Theater Address
- Trp Spyre Hydraulic Disc Brakes
- Petite And Pretty Gloss Balm
- Legal Folder Dimensions